Study of Beam Energy Spectrum Measurement in the Nlc Extraction Line

نویسندگان

  • Y. Nosochkov
  • T. O. Raubenheimer
چکیده

The NLC extraction line provides a secondary focal point with a low β function and 2 cm dispersion which can be used for measurement of the beam energy spectrum. In this study, tracking simulations were performed to transport the 0.5 TeV electron beam from the Interaction Point (IP) to the secondary focus (SF), “measure” the resultant transverse beam profile and reconstruct the disrupted IP energy spread. In the simulation, the obtained energy spectrum reproduced the initial IP spread reasonably well, especially with the vertical dispersion at SF which provides larger ratio of dispersion to the betatron beam size. More details of this study can be found in Ref. [1].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Beam Losses in the NLC Extraction Line for High Luminosity Beam Parameters November 2000

In this note we present results of beam tracking in the NLC extraction line for the NLC option with high luminosity beam parameters (Option H). Particle losses for 0.5 TeV and 1 TeV cms energy beams have been computed and examined as a function of beam offset at the interaction point (IP). Updated tracking results for the NLC Option A are presented as well. Beam Losses in the NLC Extraction Lin...

متن کامل

Nlc Beam Properties and Extraction Line Performance with Beam Offset at Ip

Properties of the disrupted NLC beam at the Interaction Point (IP) and particle loss in the extraction line are analyzed as a function of beam-to-beam position and angular offset at IP. The simulations show that disruption and beam loss maximize when the vertical beam separation at IP is about 20 times the rms vertical beam size. The horizontal offset does not increase the disruption and the be...

متن کامل

اندازه‌گیری قطبش باریکه دوترون قبل و بعد از شتاب گرفتن

Beam polarization measurement in scattering experiments with a high accuracy and the lowest possible cost is an important issue. In this regard, deuteron beam polarization was measured in the low-energy beam line easily with a relatively low cost procedure and in a very short time by Lamb Shift Polarimeter (LSP). Also, the beam polarization has been measured in high-energy beam line with BINA. ...

متن کامل

The next Linear Collider Extraction Line Design

The two main functions of the NLC extraction line include: 1) transmission of the outgoing disrupted beam and secondary particles to the dump with minimal losses; and 2) beam diagnostics and control. In this report, we describe the extraction line optics, present the results of tracking studies, and discuss the extraction line instrumentation. Presented at the 1999 IEEE Particle Accelerator Con...

متن کامل

Beam-Gas and Thermal Photon Scattering in the NLC Main Linac as a Source of Beam Halo

Scattering of primary beam electrons off of residual gas molecules or blackbody radiation photons in the NLC main linac has been identified as a potential source of beam haloes which must be collimated in the beam delivery system. We consider the contributions from four scattering mechanisms: inelastic thermal-photon scattering, elastic beam-gas (Coulomb) scattering inelastic beam-gas (Bremsstr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001