Evaluation of high-resolution pinhole SPECT using a small rotating animal.

نویسندگان

  • J B Habraken
  • K de Bruin
  • M Shehata
  • J Booij
  • R Bennink
  • B L van Eck Smit
  • E Busemann Sokole
چکیده

UNLABELLED Ex vivo measurements in animals are used frequently in the field of nuclear medicine for the characterization of newly developed radioligands and for drug development. In vivo SPECT would replace these ex vivo measurements in a relatively large number of cases if one were able to adequately image small organs. The pinhole collimator has been used extensively to obtain greater detail in planar imaging. However, using a pinhole collimator for SPECT is difficult because it requires a heavy collimated detector to rotate around a small object with a constant radius of rotation. METHODS We have developed a mechanism in which the gantry and collimator are fixed and the animal rotates. Hollow cylinders of different sizes were made to enable imaging of small animals of different sizes: mice, hamsters, and rats. The cylinder is mounted on a stepping motor-driven system and positioned exactly above the pinhole collimator of an ARC3000 camera with a 1-mm pinhole insert. The stepping motor is controlled by the Hermes acquisition/processing system. After imaging each projection, a signal is given to rotate the stepping motor with the desired number of angular degrees. Filtered backprojection, adapted to pinhole SPECT, was used for reconstruction. The system allows adjustments of the radius of rotation and along the axis of the cylinder to select the field of view. Calibration experiments were performed to ensure that the axis of rotation was exactly in the middle of the cylinder. Phantom experiments were performed to assess sensitivity, spatial resolution, and uniformity of the system and to test the system for distortion artifacts. In addition, a brain dopamine transporter rat study and a hamster myocardial study were performed to test the clinical feasibility of the entire system. RESULTS In the line source experiment, the spatial resolution obtained in air was 1.3 mm full width at half maximum, with a radius of rotation of 33 mm. Furthermore, the system has good uniformity and is capable of detecting cold spots of 2-mm diameter. The animal studies showed that it was feasible to image receptors or transporters and organs with sufficient detail in a practical setup. CONCLUSION A rotating cylinder mechanism for pinhole SPECT is feasible and shows the same characteristics as conventional pinhole SPECT with a rotating camera head, without distortion artifacts. This mechanism permits pinhole SPECT to replace many ex vivo animal experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...

متن کامل

Use of a compact pixellated gamma camera for small animal pinhole SPECT imaging.

OBJECTIVES Pinhole SPECT which permits in vivo high resolution 3D imaging of physiological functions in small animals facilitates objective assessment of pharmaceutical development and regenerative therapy in pre-clinical trials. For handiness and mobility, the miniature size of the SPECT system is useful. We developed a small animal SPECT system based on a compact high-resolution gamma camera ...

متن کامل

CoALA-SPECT: a coded aperture laboratory animal SPECT system for pre clinical imaging

We have previously demonstrated the potential of multi-pinhole coded apertures when used in conjunction with compact pixelated detectors for high resolution, high sensitivity small animal SPECT. We are now constructing a prototype SPECT system with three such detectors mounted on a rotating gantry. Each detector comprises a 12 cm diameter circular array of NaI(Tl) crystals, each 1x1x5 mm3 on a ...

متن کامل

A clinical gamma camera-based pinhole collimated system for high resolution small animal SPECT imaging.

The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct ...

متن کامل

Evaluating performance of a pixel array semiconductor SPECT system for small animal imaging.

OBJECTIVES Small animal imaging has recently been focused on basic nuclear medicine. We have designed and built a small animal SPECT imaging system using a semiconductor camera and a newly designed collimator. We assess the performance of this system for small object imaging. METHODS We employed an MGC 1500 (Acrorad Co.) camera including a CdTe semiconductor. The pixel size was 1.4 mm/pixel. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 42 12  شماره 

صفحات  -

تاریخ انتشار 2001