Safety of Nighttime 2-Hour Suspension of Basal Insulin in Pump-Treated Type 1 Diabetes Even in the Absence of Low Glucose
نویسندگان
چکیده
OBJECTIVE An integrated sensor-augmented pump system has been introduced that interrupts basal insulin infusion for 2 h if patients fail to respond to low-glucose alarms. It has been suggested that such interruptions of basal insulin due to falsely low glucose levels detected by sensor could lead to diabetic ketoacidosis. We hypothesized that random suspension of basal insulin for 2 h in the overnight period would not lead to clinically important increases in blood β-hydroxybutyrate levels despite widely varying glucose values prior to the suspension. RESEARCH DESIGN AND METHODS Subjects measured blood glucose and blood β-hydroxybutyrate levels using a meter each night at 9:00 p.m., then fasted until the next morning. On control nights, the usual basal rates were continued; on experimental nights, the basal insulin infusion was reprogrammed for a 2-h zero basal rate at random times after 11:30 p.m. RESULTS In 17 type 1 diabetic subjects (mean age 24 ± 9 years, diabetes duration 14 ± 11 years, A1C level 7.3 ± 0.5% [56 mmol/mol]), blood glucose and blood β-hydroxybutyrate levels were similar at 9:00 p.m. on suspend nights (144 ± 63 mg/dL and 0.09 ± 0.07 mmol/L) and nonsuspend nights (151 ± 65 mg/dL and 0.08 ± 0.06 mmol/L) (P = 0.39 and P = 0.47, respectively). Fasting morning blood glucose levels increased after suspend nights compared with nonsuspend nights (191 ± 68 vs. 141 ± 75 mg/dL, P < 0.0001), and the frequency of fasting hypoglycemia decreased the morning following suspend nights (P < 0.0001). Morning blood β-hydroxybutyrate levels were slightly higher after suspension (0.13 ± 0.14 vs. 0.09 ± 0.11 mmol/L, P = 0.053), but the difference was not clinically important. CONCLUSIONS Systems that suspend basal insulin for 2 h are safe and do not lead to clinically significant ketonemia even if the blood glucose level is elevated at the time of the suspension.
منابع مشابه
Suspension of basal insulin to avoid hypoglycemia in type 1 diabetes treated with insulin pump
UNLABELLED Treatment with continuous s.c. insulin infusion (CSII) provides better glycemic control and lower risk of hypoglycemia than conventional therapy with multiple daily insulin injections. These benefits have been related to a more reliable absorption and an improved pharmacokinetic profile of insulin delivered through CSII therapy. However, even for patients treated with CSII, exaggerat...
متن کاملA Continuous Glucose Monitoring System (CGMS) - a promising approach for improving metabolic control in persons with type 1 Diabetes mellitus treated by insulin pumps.
This pilot study deals with the possibilities of a Continuous Glucose Monitoring System (CGMS, Minimed- Medtronic) to optimize insulin substitution. Ten persons with type 1 diabetes mellitus treated by means of an insulin pump entered the study and eight of them completed the protocol. CGMS was introduced for a period of 5 days. The standard dinner (60 g of carbohydrates) and overnight fasting ...
متن کاملInduction of type 2 diabetes with high concentration and long term fructose intake in male Sprague-Dawley rats
Introduction: High calorie diet is becoming the most important health problem in most developed western societies. Diets with high caloric contents such as high fructose intake are associated with increasing risk of type two diabetes (T2D) and insulin resistance (IR). However, large differences have been seen in the dose and duration of fructose consumption to induction of T2D. Interest to deve...
متن کاملFrequency of Morning Ketosis After Overnight Insulin Suspension Using an Automated Nocturnal Predictive Low Glucose Suspend System
OBJECTIVE To assess the effect of overnight insulin pump suspension in an automated predictive low glucose suspend system on morning blood glucose and ketone levels in an attempt to determine whether routine measurement of ketone levels is useful when a closed-loop system that suspends insulin delivery overnight is being used. RESEARCH DESIGN AND METHODS Data from an in-home randomized trial ...
متن کاملInsulin Pump Therapy With Automated Insulin Suspension in Response to Hypoglycemia
OBJECTIVE To evaluate a sensor-augmented insulin pump with a low glucose suspend (LGS) feature that automatically suspends basal insulin delivery for up to 2 h in response to sensor-detected hypoglycemia. RESEARCH DESIGN AND METHODS The LGS feature of the Paradigm Veo insulin pump (Medtronic, Inc., Northridge, CA) was tested for 3 weeks in 31 adults with type 1 diabetes. RESULTS There were ...