Semi-automatic quantification of 4D left ventricular blood flow

نویسندگان

  • Jonatan Eriksson
  • Carl Johan Carlhäll
  • Petter Dyverfeldt
  • Jan Engvall
  • Ann F Bolger
  • Tino Ebbers
چکیده

BACKGROUND The beating heart is the generator of blood flow through the cardiovascular system. Within the heart's own chambers, normal complex blood flow patterns can be disturbed by diseases. Methods for the quantification of intra-cardiac blood flow, with its 4D (3D+time) nature, are lacking. We sought to develop and validate a novel semi-automatic analysis approach that integrates flow and morphological data. METHOD In six healthy subjects and three patients with dilated cardiomyopathy, three-directional, three-dimensional cine phase-contrast cardiovascular magnetic resonance (CMR) velocity data and balanced steady-state free-precession long- and short-axis images were acquired. The LV endocardium was segmented from the short-axis images at the times of isovolumetric contraction (IVC) and isovolumetric relaxation (IVR). At the time of IVC, pathlines were emitted from the IVC LV blood volume and traced forwards and backwards in time until IVR, thus including the entire cardiac cycle. The IVR volume was used to determine if and where the pathlines left the LV. This information was used to automatically separate the pathlines into four different components of flow: Direct Flow, Retained Inflow, Delayed Ejection Flow and Residual Volume. Blood volumes were calculated for every component by multiplying the number of pathlines with the blood volume represented by each pathline. The accuracy and inter- and intra-observer reproducibility of the approach were evaluated by analyzing volumes of LV inflow and outflow, the four flow components, and the end-diastolic volume. RESULTS The volume and distribution of the LV flow components were determined in all subjects. The calculated LV outflow volumes [ml] (67 +/- 13) appeared to fall in between those obtained by through-plane phase-contrast CMR (77 +/- 16) and Doppler ultrasound (58 +/- 10), respectively. Calculated volumes of LV inflow (68 +/- 11) and outflow (67 +/- 13) were well matched (NS). Low inter- and intra-observer variability for the assessment of the volumes of the flow components was obtained. CONCLUSIONS This semi-automatic analysis approach for the quantification of 4D blood flow resulted in accurate LV inflow and outflow volumes and a high reproducibility for the assessment of LV flow components.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of 4D Left Ventricular Blood Flow in Health and Disease

........................................................................................................................................... I POPULÄRVETENSKAPLIG SAMMANFATTNING.................................................................... III LIST OF PAPERS................................................................................................................................. V AB...

متن کامل

Quantification of left ventricular volumes and function in anesthetized beagles using real-time three-dimensional echocardiography: 4D-TomTec™ analysis versus 4D-AutLVQ™ analysis in comparison with cardiac magnetic resonance imaging

BACKROUND Real-time three-dimensional echocardiography (RT3DE) enables accurate volume determination of the left ventricle (LV), since measurements in foreshortened depicted views are avertable. Different analyzing programs are available for this RT3DE. The commonly used semi-automatic software 4D-AutLVQ™ showed underestimation of LV volumes in comparison with CMRI in healthy anesthetized dogs ...

متن کامل

Global left ventricular function quantification with CMR 4D Flow

Background 4D MR flow is a rapidly evolving technique, offering both anatomical and functional information in just a single acquisition and if successful, in the future, the 4D flow sequence should replace the 2D MR sequences. The purpose of this study is to use the anatomical information from the 4D flow sequence to assess the global left ventricular function and compare these results with the...

متن کامل

Atlas-based analysis of 4D flow CMR: Automated vessel segmentation and flow quantification

BACKGROUND Flow volume quantification in the great thoracic vessels is used in the assessment of several cardiovascular diseases. Clinically, it is often based on semi-automatic segmentation of a vessel throughout the cardiac cycle in 2D cine phase-contrast Cardiovascular Magnetic Resonance (CMR) images. Three-dimensional (3D), time-resolved phase-contrast CMR with three-directional velocity en...

متن کامل

Accuracy and Inter observer variability of blood flow quantification on 4D flow MRI in adult with transposition of the great arteries corrected by arterial switch

Background 4D flow magnetic resonance imaging appears as a reliable tool for blood flow quantification. However, in patients with transposition of the great arteries corrected by arterial switch, the choice of a high velocity encoding (venc) to avoid velocity aliasing due to pulmonary stenosis, could decrease the accuracy of blood flow quantification in vessels such as superior or inferior vena...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -