Cobaltabisdicarbollide anion receptor for enantiomer-selective membrane electrodes.
نویسندگان
چکیده
A potentiometric sensor for enantiomers has been prepared with no chiral additives, only cobaltabisdicarbollide and the protonated enantiomer.
منابع مشابه
Application of the cobaltabisdicarbollide anion to the development of ion selective PVC membrane electrodes for tuberculosis drug analysis.
The cobaltabisdicarbollide anion is used as a new material able to generate an ion-pair complex used for PVC membrane ion selective electrodes.
متن کاملComparison of the vanadyl-selective electrodes prepared by sol–gel and PVC membrane techniques
Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...
متن کاملPotassium-Selective Membrane Sensor Based on Two Recently Synthesized Poly(oxyethylene) Derivatives
Two poly(oxyethylene) derivatives 1.10-bis(2'-benzoic acid)-1,4,7,1-tetradecane (L1) and 1,7-bis(2'-benzoic acid)-1,4,7-trioxaheptane (L2) were used as suitable ionophores for the preparation of potassium-selective PVC-membrane electrodes. The resulting electrodes based on L1 and L2 exhibit linear responses to the activity of K+ ions within the concentration ranges of 3.1<em...
متن کاملMembrane-dialyzer Injection Loop for Enhancing the Selectivity of Anion-responsive Liquid-membrane Electrodes in Flow Systems
A general approach for enhancing the selectivity of anion-responsive liquid-membrane electrodes is described. The method is based on use of the receptor channel of a flowthrough dialyzer unit as the injection loop in a flow-injection system. An appropriate membrane in the dialyzer prevents ionic interferents from reaching an inselective electrode in the final flow stream The concept is demonstr...
متن کاملAnion-selective membrane electrodes based on metalloporphyrins: The influence of lipophilic anionic and cationic sites on potentiometric selectivity.
The role of lipophilic anionic and cationic additives on the potentiometric anion selectivities of polymer membrane electrodes prepared with various metalloporphyrins as anion selective ionophores is examined. The presence of lipophilic anionic sites (e.g. tetraphenylborate derivatives) is shown to enhance the non-Hofmeister anion selectivities of membranes doped with In(III) and Sn(IV) porphyr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chemical communications
دوره 33 شماره
صفحات -
تاریخ انتشار 2009