Spatial variability and reproducibility of GABA‐edited MEGA‐LASER 3D‐MRSI in the brain at 3 T
نویسندگان
چکیده
The reproducibility of gamma-aminobutyric acid (GABA) quantification results, obtained with MRSI, was determined on a 3 T MR scanner in healthy adults. In this study, a spiral-encoded, GABA-edited, MEGA-LASER MRSI sequence with real-time motion-scanner-instability corrections was applied for robust 3D mapping of neurotransmitters in the brain. In particular, the GABA+ (i.e. GABA plus macromolecule contamination) and Glx (i.e. glutamate plus glutamine contamination) signal was measured. This sequence enables 3D-MRSI with about 3 cm3 nominal resolution in about 20 min. Since reliable quantification of GABA is challenging, the spatial distribution of the inter-subject and intra-subject variability of GABA+ and Glx levels was studied via test-retest assessment in 14 healthy volunteers (seven men-seven women). For both inter-subject and intra-subject repeated measurement sessions a low coefficient of variation (CV) and a high intraclass correlation coefficient (ICC) were found for GABA+ and Glx ratios across all evaluated voxels (intra-/inter-subject: GABA+ ratios, CV ~ 8%-ICC > 0.75; Glx ratios, CV ~ 6%-ICC > 0.70). The same was found in selected brain regions for Glx ratios versus GABA+ ratios (CV varied from about 5% versus about 8% in occipital and parietal regions, to about 8% versus about 10% in the frontal area, thalamus, and basal ganglia). These results provide evidence that 3D mapping of GABA+ and Glx using the described methodology provides high reproducibility for application in clinical and neuroscientific studies.
منابع مشابه
3D GABA imaging with high spatial resolution at 3T using a navigated MEGA-LASER MRSI sequence
3D GABA imaging with high spatial resolution at 3T using a navigated MEGA-LASER MRSI sequence Wolfgang Bogner, Borjan Gagoski, Aaron T Hess, Bernhard Strasser, Himanshu Bhat, Dylan Tisdall, Andre J.W. van der Kouwe, Ellen Grant, Siegfried Trattnig, Bruce Rosen, and Ovidiu C Andronesi High-field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Medical University Vienna, Vien...
متن کاملQuantification of GABA, glutamate and glutamine in a single measurement at 3 T using GABA‐edited MEGA‐PRESS
γ-Aminobutyric acid (GABA) and glutamate (Glu), major neurotransmitters in the brain, are recycled through glutamine (Gln). All three metabolites can be measured by magnetic resonance spectroscopy in vivo, although GABA measurement at 3 T requires an extra editing acquisition, such as Mescher-Garwood point-resolved spectroscopy (MEGA-PRESS). In a GABA-edited MEGA-PRESS spectrum, Glu and Gln co-...
متن کاملDiurnal stability of gamma-aminobutyric acid concentration in visual and sensorimotor cortex.
PURPOSE To establish the diurnal stability of edited magnetic resonance spectroscopy measurements of gamma-aminobutyric acid (GABA) in visual and sensorimotor regions of the brain. MATERIALS AND METHODS GABA measurements were made in two regions of the brain (an occipital, "visual" region and a "sensorimotor" region centered on the precentral gyrus) using the MEGA-PRESS editing method, scanni...
متن کاملArtefact minimized spectral editing at 7T: quick and accurate in-vivo detection of GABA
Introduction: Spectral editing techniques are used in MRS to improve the detection of low concentrated metabolites like GABA [1], of which signals are overlapped with resonances of other highly concentrated compounds, such as Creatine and macromolecules. However, these methods rely on subtraction of two in vivo MR spectra and, therefore, are prone to artefacts. MRS at high field benefits from h...
متن کاملGABA editing at 3T with Macromolecule Suppression: MEGA-SPECIAL
Introduction. One commonly used method for in-vivo magnetic resonance spectroscopy (MRS) detection of γ-aminobutyric acid (GABA) is the MEGA-PRESS technique [1], which enables direct observation of the GABA resonance at 3.02 ppm. Unfortunately, direct quantification of GABA using MEGA-PRESS is complicated by co-editing of macromolecule (MM) signals, which also resonate at 3.02 ppm [2]. Two meth...