Cardiac functional analysis by free-breath real-time cine CMR with a spatiotemporal filtering method, TSENSE: comparison with breath-hold cine CMR.
نویسندگان
چکیده
The aim of this study was to assess the accuracy of cardiac functional values obtained from free-breathing real-time cine CMR with the temporal sensitivity encoding (TSENSE) technique by comparing them with values obtained from conventional cine CMR. For the real-time cine CMR, two protocols were employed, one with good temporal resolution and one with good spatial resolution. The functional values obtained from the high temporal resolution real-time cine CMR agreed and correlated well with those of cine CMR. On the other hand, statistically significant but clinically slight overestimation of ESV (p < .05) and underestimation of EF (p < .01) were observed with the other protocol. Real-time cine CMR with TSENSE can provide acceptable cardiac functional values.
منابع مشابه
Compressed sensing real-time cine cardiovascular magnetic resonance: accurate assessment of left ventricular function in a single-breath-hold
BACKGROUND Cardiovascular cine magnetic resonance (CMR) accelerated by compressed sensing (CS) is used to assess left ventricular (LV) function. However, it is difficult for prospective CS cine CMR to capture the complete end-diastolic phase, which can lead to underestimation of the end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF), compared to retrospective standard ci...
متن کاملHighly-Accelerated Real-Time Cine MRI using compressed sensing and parallel imaging
Introduction Breath-hold cine MRI with balanced steady-steady free precession (b-SSFP) may yield non diagnostic image quality in patients with impaired breath-hold capacity and/or arrhythmias. In such patients, it may be necessary to perform real-time cine MRI. Currently, dynamic parallel imaging methods, such as TSENSE [1] and TGRAPPA [2], can be used to achieve only moderate acceleration rate...
متن کاملThe impact of dual-source parallel radiofrequency transmission with patient-adaptive shimming on the cardiac magnetic resonance in children at 3.0 T
The cardiac magnetic resonance (CMR) of children at 3.0 T presents a unique set of technical challenges because of their small cardiac anatomical structures, fast heart rates, and the limited ability to keep motionless and hold breathe, which could cause problems associated with field inhomogeneity and degrade the image quality. The aim of our study was to evaluate the effect of dual-source par...
متن کاملLeft ventricular function, aortic velocity, and late gadolinium enhancement assessed by real-time and single shot CMR is comparable to breath-held segmented imaging: a prospective study
Methods Thirteen patients referred to the CMR lab for evaluation of undiagnosed cardiomyopathy were prospectively enrolled. All patients were in regular cardiac rhythm and able to breath-hold. Standard segmented k-space images (including cine, velocity mapping (VM), and late-gadolinium enhancement (LGE)) were acquired during breathhold; real-time images (including cine, VM, and LGE) were acquir...
متن کاملNovel highly accelerated real-time CINE-MRI featuring compressed sensing with k-t regularization in comparison to TSENSE segmented and real-time Cine imaging
Background In patients with breath-holding difficulties or arrhythmia, real-time CINE-MRI is preferred over segmented acquisitions in one breath-hold. However, common real-time sequences require a deteriorating trade-off between spatial and temporal resolution. In the current work, highly accelerated real-time CINE-MRI which features compressed sensing with k t regularization [1] was evaluated ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
دوره 8 6 شماره
صفحات -
تاریخ انتشار 2006