The assessment of feto-maternal hemorrhage in an artificial model using anti-D and anti-fetal hemoglobin antibody by flow cytometry.
نویسندگان
چکیده
BACKGROUND When fetal red cells enter the maternal circulation from placenta, an event would be happened that is described as feto-maternal hemorrhage (FMH). This life-threatening condition could be detected by using RBC antigens (surface antigens and intracellular antigens). Therefore, the measurement of fetal RBC in an artificial model would be useful to calculate FMH and consequently the dosage of Rhogam for prophylaxis. The aim of the present study was to evaluate FMH in an artificial mixture model. METHODS A series of 40 artificial specimens were prepared consisting of Rh(D) negative adult blood (non-immunized) spiked with varying amounts of Rh(D) positive cord blood from mothers between 20-30 years old in Shahid Beheshti Hospital, Tehran, Iran. Monoclonal anti-D and anti-HbF (fetal hemoglobin) were used for detection of fetal RBC in artificial mixture sample modeling. RESULTS This study showed that the percentage of fetal cells in artificial sample for anti-D antigen is in ranges of 0.28%-0.32% for a 0.25% dilution mixture, and 1.3%-2.05% for the mixture with dilution 2%. In addition, the ranges of data for anti-HbF staining was obtained 0.2%-0.34% for the 0.25% dilution sample, and the ranges of 1.04-1.8% for the 2% dilution. The regression analysis indicated that the correlation of anti-D assessment with expected standard method was r2 = 0.9672 and anti-HbF assessment was r2 = 0.8842. CONCLUSION Although both molecule targets could be used for detection of fetal RBC, in this model, anti-D staining was more accurate than anti-HbF staining. However, since anti-D can not be utilized for low-density or weak phenotype and other incompatibility, the anti-HbF labeling could be used for all FMH.
منابع مشابه
The Assessment of Feto-Maternal Hemorrhage in an Artificial Model Using Anti-D and Anti-Fetal Hemoglobin Antibody by Flow Cytometry
Background: When fetal red cells enter the maternal circulation from placenta, an event would be happened that is described as feto-maternal hemorrhage (FMH). This life-threatening condition could be detected by using RBC antigens (surface antigens and intracellular antigens). Therefore, the measurement of fetal RBC in an artificial model would be useful to calculate FMH and consequently the do...
متن کاملEvaluation of Flow Cytometry and Kleihauer Techniques for Quantification of Fetomaternal Hemorrhage: A Prospective Cohort Study in Southwestern Iran
Background: Quantification of fetal red blood cells (RBCs) in maternal blood is of great importance to calculate appropriate dose of post-deliver anti D immunoglobulin in a rhesus D (RhD)-negative woman. Objective: The aim of this study is to evaluate a direct immunofluorescence flow cytometry technique in artificial and clinical samples and compared it t...
متن کاملFeto-maternal haemorrhage assessment in a woman with a large population of red blood cells containing fetal haemoglobin.
BACKGROUND FMH quantification is necessary to calculate an individual dose of prophylactic anti-RhD immunoglobulin and to diagnose fetal anaemia causes. We encountered a healthy woman with a numerous RBCs containing fetal haemoglobin (HbF). AIMS To investigate the cause of this sign and the correct evaluation of fetal RBCs in maternal circulation. MATERIALS AND METHODS Patients samples and ...
متن کاملAssessment of fetal-maternal haemorrhage in mothers with hereditary persistence of fetal haemoglobin.
Kleihauer examination of peripheral blood cannot be used reliably to detect transplacental fetal-maternal haemorrhage in mothers with hereditary persistence of fetal haemoglobin (HPFH). In Rh(D) negative pregnancies diagnostic confusion with a large fetal-maternal haemorrhage could result in the administration of inappropriately excessive amounts of anti-D immunoglobulin, and the inability to d...
متن کاملComparison of Two Flow Cytometric Methods for Detection of Human Invariant Natural Killer T Cells (iNKT)
Background: Invariant natural killer cells (iNKT) are an important immunoregulatory T cell subset. Currently several flow cytometry-based approaches exist for the identifi-cation of iNKT cells, which rely on using the 6B11 monoclonal antibody or a combina-tion of anti-Vα24 and anti-Vβ11 antibodies. Objective: The aim of this study was to compare the ability of two flow cytometry-based methods f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Iranian biomedical journal
دوره 12 1 شماره
صفحات -
تاریخ انتشار 2008