Clinical and Procedural Outcomes of 5-French versus 6-French Sheaths in Transradial Coronary Interventions

نویسندگان

  • Alberto Polimeni
  • Francesco Passafaro
  • Salvatore De Rosa
  • Sabato Sorrentino
  • Daniele Torella
  • Carmen Spaccarotella
  • Annalisa Mongiardo
  • Ciro Indolfi
چکیده

The radial artery has been increasingly used for its favorable safety profile. However, no conclusive data are available on the optimal sheath size. In particular, it is seemingly difficult to weight both advantages and disadvantages of narrower versus larger sheaths size. Despite several studies were performed to compare the use of 6-Fr to the smaller 5-Fr sheaths, these were mostly small, single center-studies, yielding various results.We performed a comprehensive meta-analysis of all available studies comparing the use of 5-Fr versus 6-Fr sheaths in coronary procedures through the TRA.Studies comparing a 5-Fr versus a 6-Fr sheaths were searched for in PubMed, the Cochrane Library, and ISI Web of Knowledge databases.Studies were deemed eligible if they only included patients undergoing transradial cardiac catheterization with 5-Fr or 6-Fr system and reported at least one of these parameters: contrast dye volume, procedural success, procedural time, access complications, radial artery occlusion, and bleedings.Odds ratio (OR) and the mean difference (MD) were respectively used for dichotomous and continuous variables as summary measures. Both the random-effects model and the fixed effect models were used for computation of meta-analyses. Heterogeneity was assessed by means of the Cochrane Q test. Metaregression was calculated using the unrestricted maximal likelihood random effects model.The use of a 5-Fr system is associated with a significant lower contrast medium administration (MD = -22.20 [-36.43 to -7.96], P < 0.01) and significantly reduces bleedings (OR = 0.58 [0.38-0.90], P = 0.02), without compromising procedural success (OR = 0.95 [0.53-1.69], P = 0.86) or procedure length (OR = 0.55 [-2.58 to 3.69], P = 0.73), compared to the 6-Fr system. Despite no significant difference was observed between the groups (OR = 0.88 [0.50-1.56], P = 0.67), at metaregression RAO incidence in the 5-Fr group was increasingly lower as the percentage of women included into the study increased (P = 0.02).Some potentially interesting technical details, such as sheath length, hydrophilic coating, or periprocedural anticoagulation, were not homogeneously reported in individual studies.Results of the present meta-analysis confirm the excellent safety profile of transradial procedures both with 5-Fr and 6-Fr system. A 5-Fr system could be preferred in patients with a higher bleeding propensity or kidney injury.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of 5 French Guiding Catheters in Transradial Coronary Intervention Procedures

Background: Transradial coronary intervention (TRI) is a widely practiced procedure in Taiwan. Most TRIs are performed using 6 French guiding catheters. Use of smaller-sized vascular sheaths and guiding catheters may further decrease the incidence of vascular access complication, but demand more operator experience and skills in manipulation of the catheter. We report our experience in using 5 ...

متن کامل

The Feasibility of 5-French Transradial Coronary Intervention, as Compared with a 6-French Approach, for Treating Chronic Total Occlusion

Background and Objectives:Recent studies have shown that transradial coronary intervention (TRI) is feasible for percutaneous revascularization of chronic total occlusion (CTO). We investigated the feasibility and safety of using a 5-French catheter (5F) TRI for CTO and we compared it with that of using a 6F catheter TRI. Subjects and Methods:One hundred fifteen patients (117 lesions) who under...

متن کامل

Transradial cerebral angiography: technique and outcomes.

BACKGROUND AND PURPOSE The transradial approach is routinely used for coronary angiography, but only limited data exist regarding transradial cerebral angiography. The purpose of this report was to offer detailed procedural methods for transradial cerebral angiography to facilitate adoption of the technique. METHODS We reviewed 60 consecutive cases of transradial access used for neuroangiogra...

متن کامل

Transradial versus transfemoral method of percutaneous coronary revascularization for unprotected left main coronary artery disease: comparison of procedural and late-term outcomes.

OBJECTIVES This study intended to compare outcomes between transradial (TR) and transfemoral (TF) percutaneous revascularization in high-risk coronary anatomy. BACKGROUND The feasibility, efficacy and safety between TR and TF methods of percutaneous coronary revascularization for unprotected left main coronary artery (UPLM]) disease have not been compared. METHODS Among 821 consecutive pati...

متن کامل

Transradial Approach as a Default Route in Coronary Artery Interventions

Advances in percutaneous coronary intervention (PCI) and peri-procedural potent antithrombotic treatments during the past decade have dramatically improved the outcomes of ischemic heart disease. The femoral artery is the vascular route used in PCI in most catheterization labs. However, when the femoral artery is used as the approaching vessel, local hemorrhagic complication is not rare in the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 94  شماره 

صفحات  -

تاریخ انتشار 2015