Reproducibility of a novel echocardiographic 3D automated software for the assessment of mitral valve anatomy

نویسندگان

  • Iolanda Aquila
  • Ariana González
  • Covadonga Fernández-Golfín
  • Luis Miguel Rincón
  • Eduardo Casas
  • Ana García
  • Rocio Hinojar
  • José Julio Jiménez-Nacher
  • José Luis Zamorano
چکیده

BACKGROUND 3D transesophageal echocardiography (TEE) is superior to 2D TEE in quantitative anatomic evaluation of the mitral valve (MV) but it shows limitations regarding automatic quantification. Here, we tested the inter-/intra-observer reproducibility of a novel full-automated software in the evaluation of MV anatomy compared to manual 3D assessment. METHODS Thirty-six out of 61 screened patients referred to our Cardiac Imaging Unit for TEE were retrospectively included. 3D TEE analysis was performed both manually and with the automated software by two independent operators. Mitral annular area, intercommissural distance, anterior leaflet length and posterior leaflet length were assessed. RESULTS A significant correlation between both methods was found for all variables: intercommissural diameter (r = 0.84, p < 0.01), mitral annular area (r = 0.94, p > 0, 01), anterior leaflet length (r = 0.83, p < 0.01) and posterior leaflet length (r = 0.67, p < 0.01). Interobserver variability assessed by the intraclass correlation coefficient was superior for the automatic software: intercommisural distance 0.997 vs. 0.76; mitral annular area 0.957 vs. 0.858; anterior leaflet length 0.963 vs. 0.734 and posterior leaflet length 0.936 vs. 0.838. Intraobserver variability was good for both methods with a better level of agreement with the automatic software. CONCLUSIONS The novel 3D automated software is reproducible in MV anatomy assessment. The incorporation of this new tool in clinical MV assessment may improve patient selection and outcomes for MV interventions as well as patient diagnosis and prognosis stratification. Yet, high-quality 3D images are indispensable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of position on echocardiographic diagnosis of mitral valve prolapse

Echocardiography has been accepted as the diagnostic modality of choice for mitral valve prolapse (MVP). The determine the effect of position on echocardiographic diagnosis of MVP, we examined 693 consecutive patients referred to the echocardiography laboratory because of suspected MVP. First, patients were examined using the usual standard M-Mode echocardiography( left parasternal third or fou...

متن کامل

Fully automated software for mitral annulus evaluation in chronic mitral regurgitation by 3-dimensional transesophageal echocardiography

Three-dimensional (3D) transesophageal echocardiography (TEE) is the gold standard for mitral valve (MV) anatomic and functional evaluation. Currently, dedicated MV analysis software has limitations for its use in clinical practice. Thus, we tested here a complete and reproducible evaluation of a new fully automatic software to characterize MV anatomy in different forms of mitral regurgitation ...

متن کامل

Clinical and Electrocardiographic comparison of patients with primary Mitral Valve Prolapse Syndrome and control group

ABSTRACT: Mitral Valve Prolapse (WVP) in one of the commonest cardiac abnormalities. Echocardiography has generally been accepted as the diagnostic modality of choice, To assess the characteristic symptoms signs and electrocardiographic abnormalities of MVP results of prospective 500 age and sex matched healthy subjects without echocardiographic MVP (control subjects). The diagnostic criteria...

متن کامل

بررسی عوامل موثر در افزایش سطح دریچه و پیدایش نارسایی میترال بعد از بالون میترال والولوپلاستی در 110 بیمار در مجتمع بیمارستانی امام خمینی

Background: Percutaneous Transeptal Mitral Commisurotomy (PTMC) has been used in treating mitral stenosis with variable success, its main complication being mitral incompetence. There is a need to define the subgroup of the patients who benefit mostly from the procedure. Methods: We studied 110 patients (age 17 to 60 years mean 33.2) with mitral stenosis. PTMC was performed though femoral vein....

متن کامل

ارتباط یافته‌های اکوکاردیوگرافی با هایپرموبیلیتی مفصلی: مبتلایان به پرولاپس ایدیوپاتیک دریچه میترال در مقایسه با گروه شاهد سالم

Background: Mitral valve prolapse is a relatively common valvular abnormality in most communities and joint hypermobility (JHM) is also seen in many healthy people as well as in certain clinical disorders, such as Marfan syndrome. The present study was designed to investigate the association between joint hypermobility and mitral valve prolapse (MVP) in an Iranian population sample. Methods: F...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2015