Influence of the short-axis cine acquisition protocol on the cardiac function evaluation: A reproducibility study
نویسندگان
چکیده
PURPOSE To define the optimal cardiac short-axis cine acquisition protocol for the assessment of the left and rightventricular functions. MATERIALS AND METHODS 20 volunteers were recruited and breath-hold CINE images were acquired on a Siemens Prisma 3T MRI. Four short-axis acquisition planes were defined from the 4-chamber view. AV Junctions: short-axis slices parallel to the plane that cuts through the external right and left atrioventricular junctions. Left AV Junctions: short-axis slices parallel to the plane that cuts through both left atrioventricular junctions. Septum: short-axis slices perpendicular to the septum with one cutting through the septum junction. LongAxis: short-axis slices perpendicular to the long axis with one cutting through the septum junction. Intra and inter reproducibility was assessed using Bland-Altman coefficient of variation (CV) and Lin's concordance correlation coefficient (CCC). The influence of the protocol on the ejection fraction (EF) and stroke volume (SV) was quantified statistically using pair-wise CV and Pearson's correlation coefficient R (2). RESULTS All protocols led to high reproducibility for the LV EF (mean intra CV = 3.83%, mean inter CV = 4.81%, lowest CV = 4.20% (AV junctions) and highest CV = 5.24% (Left AV Junctions)). Reproducibility of the RV measurements was lower (mean intra CV = 7.84%, mean inter CV = 9.17%). Septum protocol led to significantly lower variability compared to the other 3 protocols for RV EF (CV = 7.62% (Septum), CV = 8.42% (Long Axis), CV = 9.54% (Left AV Junctions) and CV = 11.08% (AV Junctions) with Lin's CCC varying from 0.4 (AV Junctions) to 0.69 (Septum) for inter-observer reproducibility). No differences in group average for clinical parameters was found for both LV and RV clinical measurements. However, patient-specific RV EF evaluation is dependent on the chosen protocol (CV = 9.95%, R (2) = 0.52). CONCLUSION Based on the results of the study cine mode short-axis acquisitions should be planned perpendicular to the septum in order to guarantee optimal RV and LV measurements.
منابع مشابه
Comparison of four short axis cine acquisition protocols for the evaluation of left ventricular cardiac function
Background Guidelines from the SCMR board try to standardize the acquisition and post processing protocols for uniform and reproducible analysis of cardiac data. However, for short axis cine acquisition, the definition of the image orientation for data acquisition is not well defined, possibly leading to variation in the evaluation of the Left Ventricular cardiac function. Having a standard def...
متن کاملEvaluation of left ventricular volumes and ejection fraction using fast steady-state cine MR imaging: comparison with left ventricular angiography.
Previous studies demonstrated that magnetic resonance (MR) imaging consistently underestimated angiographic measurements of left ventricular (LV) volumes. The purpose of this study was to determine whether MR imaging with steady-state free precession acquisition (SSFP) can provide improved accuracy and reproducibility in measuring cardiac function in comparison with fast spoiled gradient echo c...
متن کاملQuantitative assessment of left ventricular mechanical dyssynchrony using cine cardiovascular magnetic resonance imaging: Inter-study reproducibility
OBJECTIVES To determine the inter-study reproducibility of left ventricular (LV) mechanical dyssynchrony measures based on standard cardiovascular magnetic resonance (CMR) cine images. DESIGN Steady-state free precession (SSFP) LV short-axis stacks and three long-axes were acquired on the same day at three time points. Circumferential strain systolic dyssynchrony indexes (SDI), area-SDI as we...
متن کاملFully automatic segmentation of short and long axis cine cardiac MR
Introduction Quantitative analysis of cardiac function requires delineation of the left ventricle (LV) in cine cardiac MR (CMR). Typically, this is done using short-axis (SA) images, however, acquisition of several long-axis (LA) views has become quite common. The latter can be used for the accurate and reproducible determination of the basal SA slice, known as one of the major inter-observer v...
متن کاملComparison of strain measurement from multimodality tissue tracking with strain-encoding MRI and harmonic ophase MRI in Pulmonary Hypertension
BACKGROUND Pixel-based multimodality tissue tracking (MTT) is a new noninvasive method for the quantification of cardiac deformation from cine image of MRI. The aim of this study is to validate bi-ventricular strain measurement by MTT compared to strain-encoding (SENC) MRI and harmonic phase (HARP) MRI in pulmonary hypertension (PH) patients. METHODS In 45 subjects (30 PH patients and 15 norm...
متن کامل