Emergency department ultrasonographic probe contamination and experimental model of probe disinfection.

نویسندگان

  • Bradley W Frazee
  • Jahan Fahimi
  • Larry Lambert
  • Arun Nagdev
چکیده

STUDY OBJECTIVE We evaluate the frequency of emergency department (ED) ultrasonographic probe contamination and the bacterial species involved and evaluate probe cleaning and disinfection methods. METHODS This was a 3-part observational cross-sectional study. Surveillance cultures were taken of linear and curvilinear probes on 3 ultrasonographic machines between patient encounters. Cultures of uncovered probes were taken immediately after scanning of skin and soft tissue infections. After experimental probe contamination with methicillin-resistant Staphylococcus aureus (MRSA), we assessed 3-step disinfection by sequential cleaning with a dry towel, saline solution-moistened towel, and quaternary ammonia germicidal wipe and 1-step disinfection by germicidal wipe alone. Cultures were obtained by applying the probe to a blood agar plate. RESULTS In part 1, of 164 surveillance cultures obtained from 6 probes on 29 sampling days during 11 months, 111 (67%; 95% confidence interval [CI] 60% to 74%) grew normal skin flora or environmental flora, 52 had no growth (32%; 95% CI 25% to 39%), and 2 (1.2%; 95% CI 0.3% to 4.3%) grew a clinically important pathogen. In part 2, 14 of 20 (70%; 95% CI 48% to 85%) cultures taken after skin and soft tissue infection scanning produced heavy growth of a clinically important pathogen, including 13 S aureus (5 MRSA). In part 3, cleaning with a dry and moist towel reduced but did not eliminate MRSA. The germicidal wipe step resulted in no growth in 15 of 15 (100%; 95% CI 80% to 100%) cultures in 3-step disinfection and in 9 of 10 (90%; 95% CI 60% to 98%) when used alone. CONCLUSION Skin and environmental flora are commonly present on ultrasonographic probes between patient encounters in our ED; however, clinically important pathogens are uncommon. S aureus (including MRSA) frequently contaminates uncovered probes during skin and soft tissue infection scanning, but in an experimental model, MRSA appears to be reliably removed by a quaternary ammonia germicidal wipe if the probe is partially cleaned first.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transvaginal ultrasound probe contamination by the human papillomavirus in the emergency department.

OBJECTIVE To determine if human papillomavirus (HPV) DNA can be detected on the transvaginal sonography (TVS) probe in the emergency department (ED) and whether the current barrier method plus disinfection can prevent HPV contamination of the TVS probe. METHODS This was a two-part cross-sectional study. In the first part, surveillance samples were taken from the TVS probe for HPV DNA detectio...

متن کامل

Emergency department ultrasound probe infection control: challenges and solutions.

Point-of-care ultrasound (US) has become a cornerstone in the diagnosis and treatment of patients in the emergency department (ED). Despite the beneficial impact on patient care, concern exists over repeat use of probes and the role as a vector for pathogen transmission. US probes are used for various applications, with the level of infection risk, based on the Spaulding Classification, ranging...

متن کامل

Ultrasonographic Examination of Mammary Glands in Caspian Mares during the Lactation and Dry Period

Objective- The aim of this study was to determine the normal ultrasonographic and morphologic appearance of mammary gland and teat in Caspian mares during lactation and dry period. Design- Experimental study. Animals- Seven mature Caspian mares Procedures- Using a 6.5-8.5 MHz linear transducer the ultrasonographic appearance of lactating and dry mammary glands was determined in 7 mature Casp...

متن کامل

A Non-Demolition Photon Counting Method by Four-Level Inverted Y-Type Atom

The semi-classical model of atom-field interaction has been fully studied for some multilevel atoms, e.g. Vee, L, Cascade X , Y, and inverted Y and so on. This issue is developed into the full-quantum electrodynamics formalism, where the probe and coupling electromagnetic fields are quantized. In this article, we investigate the full-quantum model of absorption and dispersion spectrum of trappe...

متن کامل

Disinfection of a probe used in ultrasound-guided prostate biopsy.

BACKGROUND Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. OBJECTIVE To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. METHOD The effectiveness of disinfection was determi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of emergency medicine

دوره 58 1  شماره 

صفحات  -

تاریخ انتشار 2011