Comparison of 133 xenon ventilation equilibrium scan (XV) and 99m technetium transmission (TT) scan for use in regional lung analysis by 2D gamma scintigraphy in healthy and cystic fibrosis lungs.
نویسندگان
چکیده
BACKGROUND Quantification of particle deposition in the lung by gamma scintigraphy requires a reference image for location of regions of interest (ROIs) and normalization to lung thickness. In various laboratories, the reference image is made by a transmission scan ((57)Co or (99m)Tc) or gas ventilation scan ((133)Xe or (81)Kr). There has not been a direct comparison of measures from the two methods. METHODS We compared (99m)Tc transmission scans to (133)Xe equilibrium ventilation scans as reference images for 38 healthy subjects and 14 cystic fibrosis (CF) patients for their effects on measures of regional particle deposition: the central-to-peripheral ratio of lung counts (C/P); and ROI area versus forced vital capacity. Whole right lung ROI was based on either an isocontour threshold of three times the soft tissue transmission (TT) or a threshold of 20% of peak xenon ventilation counts (XV). We used a central ROI drawn to 50% of height and of width of the whole right lung ROI and placed along the left lung margin and centered vertically. RESULTS In general, the correlation of normalized C/P (nC/P) between the two methods was strong. However, the value of nC/P was significantly smaller for the XV method than the TT method. Regression equations for the relationship of nC/P between the two methods were, for healthy subjects, y=0.75x+0.61, R(2)=0.64 using rectangular ROIs and y=0.76x+0.45, R(2)=0.66 using isocontour ROIs; and for CF patients, y=0.94x+0.46, R(2)=0.43 and y=0.85x+0.42, R(2)=0.41, respectively. CONCLUSIONS (1) A transmission scan with an isocontour outline in combination with a rectangular central region to define the lung borders may be more useful than a ventilation scan. (2) Close correlation of nC/Ps measured by transmission or gas ventilation should allow confident comparison of values determined by the two methods.
منابع مشابه
Extraosseous accumulation of Technetium-99m-Methyl Diphosphonate (99mTc-MDP) in a child with ALL: A Case Report
Extraosseous accumulation of technetium-99m-methyl diphosphonate (99mTc-MDP) on bone scan is not common. This phenomenon is often attributed to abnormality of calcium metabolism and has been reported in a variety of conditions including metabolic diseases and malignancies. A five years old boy is presented here, who was admitted to the pediatric emergency suffering from fatigue, respiratory sym...
متن کاملA clinical comparison of Xe-127 and Xe-133 for ventilation studies.
Xenon-133 and xenon-127 were compared by performing ventilation studies with both radionuclides in 19 patients with a variety of lung diseases. Assessment of the counting rate over the chest, relative to the radioactivity in the lungs, permitted the evaluation of each isotope in terms of usable photons detected by a scintillation camera with a large field of view and appropriate collimation. A ...
متن کاملSpurious lung perfusion ventilation defect on planar ventilation-perfusion scan detected by SPECT imaging
Pulmonary embolism (PE) is a preventable cause of morbidity and mortality which needs prompt recognition. Ventilation-perfusion (V/Q) scan is a well-established diagnostic test for evaluation of suspected PE. We report a 32-year-old woman with history of rheumatologic disease and acute dyspnea, who was referred for V/Q scintigraphy. The planar images revealed multiple mismatched defects through...
متن کاملRegional ventilation studies with Kr-81m and Xe-133: a comparative analysis.
Krypton-81m and Xe-133 ventilation scintigrams, and particulate per fusion scintigrams with Tc-99m, were obtained on the same day in 41 pa tients. Of 14 studies demonstrating pulmonary embolism, Kr-81m corn plernented the perfusion study better than Xe-133 in seven and was judged essential for that diagnosis in two. Xenon-133 was better in none. On the other hand, in 29 studies with obstructive...
متن کاملThe comparison between ultrasonography and 99mTc-DMSA renal scan in estimation of kidney size
Introduction: Renal length measurement is an important diagnostic clue in several urinary tract abnormalities. Although ultra sonography is the most frequent used modality for renal size estimation, renal diameter assessment by 99mTc-DMSA scintigraphy is of great value. By now, pointing to the renal size in the 99mTc-DMSA scintigraphy report has not been recommended by gui...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of aerosol medicine and pulmonary drug delivery
دوره 26 2 شماره
صفحات -
تاریخ انتشار 2013