Impact of very long time output variation in the treatment of total marrow irradiation with helical tomotherapy

نویسندگان

  • Yutaka Takahashi
  • Susanta K Hui
چکیده

BACKGROUND Beam-on time in Total Marrow Irradiation (TMI) delivery with helical tomotherapy is more than 30 minutes. The purpose of this study was to investigate extended time output variation in tomotherapy machine without dose servo system and its impact on the dosimetry of TMI planning. MATERIALS AND METHODS The calibration procedures with 1800 seconds delivery were conducted. The slab and cylindrical phantoms were used for static and rotational output variation measurements, respectively. All measurements were performed in 0.1 second interval with an Exradin A1SL ionization chamber (Standard Imaging Inc., Madison, WI, USA) connected to the tomoelectrometer supplied by the manufacture. Simulated TMI treatment planning with a slab phantom was delivered and verified with ion chamber and EDR-2 films. RESULTS The static output variations during 30 min averaged -2.9% ± 0.2%, -3.4% ± 0.3%, and -3.4% ± 0.3% at 10 min, 20 min, and 30 min, respectively. The rotational output variations from start averaged -2.5% ± 0.7%, -3.1% ± 0.7%, and -3.5% ± 0.8% at 10 min, 20 min, and 30 min, respectively. The maximum output variation was up to 4.5%. In a TMI planning model, in which beam-on time was over 30 min, planned dose and dose measured with ion chambers in both cranial and caudal sides agreed within 3%. Film measurements in cranial and caudal sides also showed the pass rates of 97.7% and 92.2% with the criteria of 3 mm/3% in gamma analysis. CONCLUSION These results suggest that long TMI delivery by helical tomotherapy, even without dose servo system, does not pose a risk for significant deviations from the original treatment plan regardless of the output variation. However, very long time output variation should be checked before the first treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Fast, simple, and informative patient-specific dose verification method for intensity modulated total marrow irradiation with helical tomotherapy

BACKGROUND Patient-specific dose verification for treatment planning in helical tomotherapy is routinely performed using a homogeneous virtual water cylindrical phantom of 30 cm diameter and 18 cm length (Cheese phantom). Because of this small length, treatment with total marrow irradiation (TMI) requires multiple deliveries of the dose verification procedures to cover a wide range of the targe...

متن کامل

Prostate Helical Tomotherapy: A semi-empirical estimation of the scaling factor based on 2D approximating field

Background: In Helical Tomotherapy (HT), the scaling factor (SF) is the time in seconds that each leaf viewing a target would need to be open to deliver the prescribed dose. The SF is patient-specific and is used to calculate the rotational period of the gantry, and the total treatment time (TTT) of the HT. The SF is generally difficult to estimate. Currently, it takes about one hour t...

متن کامل

Accelerated large volume irradiation with dynamic Jaw/Dynamic Couch Helical Tomotherapy

BACKGROUND Helical Tomotherapy (HT) has unique capacities for the radiotherapy of large and complicated target volumes. Next generation Dynamic Jaw/Dynamic Couch HT delivery promises faster treatments and reduced exposure of organs at risk due to a reduced dose penumbra. METHODS Three challenging clinical situations were chosen for comparison between Regular HT delivery with a field width of ...

متن کامل

Review of techniques for improving the uniformity of dose distribution in total body irradiation (TBI) with parallel – opposed anterior and posterior geometry

      Total body irradiation (TBI) is a kind of external beam radiotherapy which is used in conjunction with chemotherapy with the purpose of immunosuppression before bone marrow transplantation. As recommended by AAPM dose distribution uniformity in TBI is very important and dose variation must be within ±10% of prescription dose. Patients treatment geometry for TBI techniques fall into two co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013