Non-invasive assessment of pulmonary blood flow using an inert gas rebreathing device in fibrotic lung disease.

نویسندگان

  • Tamera J Corte
  • Athol U Wells
  • Michael A Gatzoulis
  • Derek Cramer
  • Simon Ward
  • Peter S Macdonald
  • Konstantinos Dimopoulos
  • Stephen J Wort
چکیده

BACKGROUND AND AIMS Pulmonary hypertension (PH) is increasingly recognised in patients with diffuse lung disease, and is associated with increased mortality. Cardiac output (CO) is a prognostic marker in PH. Non-invasive assessment of pulmonary blood flow (PBF(INNOCOR)) with the inert gas rebreathing Innocor device has been validated against CO in PH, but not in PH associated with parenchymal lung disease. PBF(INNOCOR) may be less accurate in patients with lung disease because of intrapulmonary shunting and/or incomplete gas mixing. Our aim was to determine the variability of PBF(INNOCOR) in normal subjects, before evaluating PBF(INNOCOR) in diffuse lung disease against CO measured by the indirect Fick method (CO(FICK)) at right heart catheterisation (RHC). METHODS AND RESULTS 23 normal subjects had lung volume measurements by a constant-volume body plethysmograph and three consecutive PBF(INNOCOR) measurements on the same day. 20 subjects returned for repeat assessment. PBF(INNOCOR) had good intrasession repeatability (coefficient of variation (CV)=6.57%) and intersession reproducibility (mean CO difference=0.13; single determinant SD=0.49; CV=9.7%). 28 consecutive patients with lung fibrosis referred for RHC had PBF(INNOCOR) measured within 24 h of RHC. There was good agreement between CO(FICK) and PBF(INNOCOR), with no evidence of systematic bias (mean CO(FICK) 4.3+/-1.0; PBF(INNOCOR) 4.0+/-1.2l/ min; p=0.07). Bland-Altman analysis revealed a mean difference of -0.32 and limits of agreement of -2.10 to +1.45. CONCLUSION Non-invasive PBF measured by the inert gas rebreathing Innocor device has good intrasession repeatability and intersession reproducibility. In diffuse lung disease, CO can be accurately and non-invasively measured by the Innocor device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique.

Values of effective pulmonary blood flow (Q(EP)) and cardiac output, determined by a non-invasive foreign gas rebreathing method (CO(RB)) using a new infrared photoacoustic gas analysing system, were compared with measurements of cardiac output obtained by the direct Fick (CO(FICK)) and thermodilution (CO(TD)) methods in patients with heart failure or pulmonary hypertension. In 11 patients, of ...

متن کامل

Non-invasive Assessment of Cardiac Output Using an Inert Gas Rebreathing Device: Repeatability and Reproducibility in Normal Controls

P134 Table Pre-CDM Post-CDM Z score p Value* 3 Months 0.60 (0–6) 0.22 (0–4) 25.58 ,0.001 6 Months 0.86 (0–10) 0.44 (0–5) 25.23 ,0.001 12 Months 1.14 (0–13) 0.79 (0–9) 22.82 ,0.005 *Wilcoxon rank. CDM, chronic disease management. Poster presentations Thorax 2008;63(Suppl VII):A74–A160 A127 group.bmj.com on October 20, 2017 Published by http://thorax.bmj.com/ Downloaded from

متن کامل

Cardiopulmonary response to oxygen therapy in hypoxaemic chronic airflow obstruction.

The acute change in pulmonary artery pressure in response to oxygen may have prognostic value for patients with chronic obstructive pulmonary disease treated with long term domiciliary oxygen. A study was carried out to elucidate the mechanism of the acute cardio-respiratory response to oxygen in such patients and to determine whether it can be quantified non-invasively. The effects of acute ox...

متن کامل

Non-invasive measurement of pulmonary blood flow during prone positioning in patients with early acute respiratory distress syndrome.

In the daily clinical routine at the bedside, information on effective pulmonary blood flow (PBF) is limited and requires invasive monitoring, including a pulmonary artery catheter, to determine both cardiac output and intrapulmonary shunt. Therefore we evaluated a non-invasive method for the measurement of PBF in a clinical setting, including 12 patients with acute respiratory failure (acute r...

متن کامل

Carbon dioxide narcosis due to inappropriate oxygen delivery: a case report

BACKGROUND Oxygen delivery to patients with chronic obstructive pulmonary disease may be challenging because of their potential hypoxic ventilatory drive. However, some oxygen delivery systems such as non-rebreathing face masks with an oxygen reservoir bag require high oxygen flow for adequate oxygenation and to avoid carbon dioxide rebreathing. CASE PRESENTATION A 72-year-old Caucasian man w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 65 4  شماره 

صفحات  -

تاریخ انتشار 2010