Performance of the Oxoid M.I.C.Evaluator™ Strips compared with the Etest® assay and BSAC agar dilution

نویسندگان

  • Shazad Mushtaq
  • Marina Warner
  • Jonathan Cloke
  • Mariya Afzal-Shah
  • David M. Livermore
چکیده

OBJECTIVES The Oxoid M.I.C.Evaluator (M.I.C.E; Thermo Fisher Scientific) comprises an antibiotic gradient on a plastic support. We compared its performance with Etest--a similar product--using BSAC agar dilution as a reference. METHODS Parallel MIC tests were performed by M.I.C.Evaluator, Etest and agar dilution on Iso-Sensitest agar. In total, 9354 organism/strip combinations were tested by each method, using 1017 bacteria representing clinically important fastidious and non-fastidious species. RESULTS Essential agreement of strip MIC values (+/-1 doubling dilution) with the agar dilution reference, with off-scale results excluded, was 89.9% for M.I.C.Evaluator versus 89.5% for Etest (P > 0.05). These proportions were similar, at 89.5% and 89.3% (P > 0.05), respectively, if off-scale values were counted as agreeing if they could agree (e.g. a strip MIC >32 mg/L and an agar dilution MIC of 128 mg/L). For both strips, agreement with agar dilution was best for non-fastidious genera, Moraxella, Listeria, Pasteurella and Campylobacter spp. and weaker for streptococci, anaerobes, Neisseria spp. and, especially, Haemophilus influenzae. Many 'disagreements', especially for H. influenzae, concerned organisms unequivocally resistant by all methods (e.g. ampicillin MIC 256 mg/L by agar dilution, 16 or 32 mg/L by both strips); nevertheless both strips underestimated imipenem MICs for Proteus. There was no difference between the two strip types in the proportion of agreements with agar dilution (P > 0.05); nevertheless their results agreed better with each other than with agar dilution (P < 0.01). CONCLUSIONS The M.I.C.Evaluator performed almost identically to the Etest, giving good agreement with BSAC agar dilution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comment on: Performance of the Oxoid M.I.C.Evaluator™ Strips compared with the Etest® assay and BSAC agar dilution.

Sir, We read with great interest the study published by Mushtaq et al. about the performance of Oxoid M.I.C.EvaluatorTM (M.I.C.E.) (Thermo Fisher Scientific, Basingstoke, UK) strips compared with those of the Etest (AB bioMérieux, Marcy l’Étoile, France) and agar dilution for determination of MICs using the BSAC guidelines. We recently had the opportunity to carry out a similar study that compa...

متن کامل

Calcium-supplemented daptomycin Etest strips for susceptibility testing on Iso-Sensitest agar.

OBJECTIVE Iso-Sensitest agar (ISA), which is recommended by the BSAC for routine susceptibility testing of staphylococci and enterococci, contains insufficient calcium for testing daptomycin. Isotonic agar supplemented with 50 mg/L calcium has been advocated, but is not routinely available in many laboratories. We evaluated a daptomycin Etest that incorporates a constant level of calcium throug...

متن کامل

Phenotypic detection of mecC-MRSA: cefoxitin is more reliable than oxacillin.

OBJECTIVES To investigate the reliability of cefoxitin and oxacillin for the detection of mecC-positive Staphylococcus aureus. METHODS The susceptibility to cefoxitin and oxacillin of 62 mecC-positive S. aureus isolates was investigated using broth microdilution, agar dilution, Etest and disc diffusion on different types of media. The data were interpreted for the utility of cefoxitin and oxa...

متن کامل

Comparison of M.I.C.E. and Etest with CLSI Agar Dilution for Antimicrobial Susceptibility Testing against Oxacillin-Resistant Staphylococcus spp

OBJECTIVE The main objective of this study was to comparatively evaluate the performance of M.I.C.E. and Etest methodologies to that of agar dilution for determining the antimicrobial susceptibility profile of oxacillin-resistant Staphylococcus spp. METHODS A total of 100 oxacillin-resistant Staphylococcus spp. isolates were collected from hospitalized patients at a teaching hospital. Antimic...

متن کامل

Breakpoints for predicting Pseudomonas aeruginosa susceptibility to inhaled tobramycin in cystic fibrosis patients: use of high-range Etest strips.

Inhaled administration of tobramycin assures high concentrations in cystic fibrotic lungs, improving the therapeutic ratio over that of parenteral tobramycin levels, particularly against Pseudomonas aeruginosa. Conventional Clinical and Laboratory Standards Institute (CLSI; formerly National Committee for Clinical Laboratory Standards) breakpoints only consider parenteral levels and do not take...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 65  شماره 

صفحات  -

تاریخ انتشار 2010