Determination of selenium in serum in the presence of gadolinium with ICP-QQQ-MS.

نویسندگان

  • David P Bishop
  • Dominic J Hare
  • Fred Fryer
  • Regina V Taudte
  • Barbara R Cardoso
  • Nerida Cole
  • Philip A Doble
چکیده

Gadolinium (Gd)-based magnetic resonance imaging (MRI) contrasting agents interfere with the determination of selenium (Se) when analysed by single quadrupole inductively coupled plasma-mass spectrometry (ICP-MS). This paper demonstrates that an ICP-triple quadrupole-MS (ICP-QQQ-MS) with oxygen mass shift overcomes Gd(++) interference on Se(+) and mitigates typically encountered matrix and spectral based interferences. Normal human serum was diluted in a solution containing isopropanol, EDTA, NH4OH and Triton X-100. Samples were unspiked (control) serum; serum spiked with 0.127 μmol L(-1) Se or 127 μmol L(-1) Gd; and serum spiked with both 0.127 μmol L(-1) Se and 127 μmol L(-1) Gd. Consideration of collision/reaction gases and conditions for interference mitigation included helium (He); a 'low' and 'high' hydrogen (H2) flow, and oxygen (O2). The instrument tune for O2 was optimised for effective elimination of interferences via a mass shift reaction of Se(+) to SeO(+). The ICP-QQQ-MS was capable of detecting trace (>9.34 nmol L(-1)) levels of Se in serum in the presence of Gd in our simulated post-MRI serum sample. The multi-tune capabilities of the ICP-QQQ-MS may be adapted to eliminate other specific isobaric interferences that cause false positive results in other analyses where the analyte is confounded by doubly charged and/or polyatomic species.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Agilent 8800 Triple Quadrupole ICP-MS: Understanding oxygen reaction mode in ICP-MS/MS

The use of oxygen as a reaction gas for the removal of interferences in quadrupole ICP-MS is well established. However, prior to the development of the Agilent 8800 Triple Quadrupole ICP-MS (ICP-QQQ), the use of oxygen had been limited to determination of a small number of analytes in simple, well defined matrices. This is because oxygen can react with matrix components, analytes and polyatomic...

متن کامل

Low-level Selenium Determination

Introduction Selenium is an essential element to human health at low levels (2080 μg/L), but becomes toxic at elevated levels. Selenium exists in different forms that determine its toxicity and bioavailability. Current research is now focusing on the determination of individual selenium species or seleniumcontaining compounds. This can be done using ICP-MS as a selenium-specific detector for a ...

متن کامل

Determination of Chromium, Selenium, and Molybdenum in Nutritional Products by ICP-MS Authors

An ICP-MS validated method for the rapid determination of chromium (Cr), selenium (Se), and molybdenum (Mo) in infant formula and adult nutritional products was successfully transferred from the Agilent 7500cx ICP-MS to the Agilent 7700x ICP-MS, and from lab 1 to lab 2, respectively. The key advantage of the method is that all samples can be analyzed using a single-cell gas mode (helium mode) t...

متن کامل

The Interference Free Determination of Selenium in Environmental and Clinical Samples

The Interference Free Determination of Selenium in Environmental and Clinical Samples by ICP-MS Justine Clare Turner The determination of selenium in environmental and clinical samples by ICP-MS is complicated by both poor sensitivity and severe interferences resulting from both the sample matrix and the argon plasma. The purpose of this study was to investigate ways of overcoming these problem...

متن کامل

The Use of Collision/Reaction Cell ICP-MS with Isotope Dilution to Provide Assigned Values for Zn, Cu, and Se in Serum Samples for a Proficiency Testing Scheme

This work describes a procedure for the determination of copper, selenium, and zinc in serum using the Agilent 7500ce collision/reaction cell (CRC) ICP-MS in both helium and hydrogen modes. The method utilizes the high-accuracy technique of isotope dilution whereby the sample is spiked with an isotopically enriched solution to an optimum ratio and measured alongside a spiked calibration standar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 140 8  شماره 

صفحات  -

تاریخ انتشار 2015