Mandibular reconstruction using an axially vascularized tissue-engineered construct

نویسندگان

  • Ahmad M Eweida
  • Ayman S Nabawi
  • Mona K Marei
  • Mohamed R Khalil
  • Habashi A Elhammady
چکیده

BACKGROUND Current reconstructive techniques for continuity defects of the mandible include the use of free flaps, bone grafts, and alloplastic materials. New methods of regenerative medicine designed to restore tissues depend mainly on the so-called extrinsic neovascularization, where the neovascular bed originates from the periphery of the construct. This method is not applicable for large defects in irradiated fields. METHODS We are introducing a new animal model for mandibular reconstruction using intrinsic axial vascularization by the Arterio-Venous (AV) loop. In order to test this model, we made cadaveric, mechanical loading, and surgical pilot studies on adult male goats. The cadaveric study aimed at defining the best vascular axis to be used in creating the AV loop in the mandibular region. Mechanical loading studies (3 points bending test) were done to ensure that the mechanical properties of the mandible were significantly affected by the designed defect, and to put a base line for further mechanical testing after bone regeneration. A pilot surgical study was done to ensure smooth operative and post operative procedures. RESULTS The best vascular axis to reconstruct defects in the posterior half of the mandible is the facial artery (average length 32.5 ± 1.9 mm, caliber 2.5 mm), and facial vein (average length 33.3 ± 1.8 mm, caliber 2.6 mm). Defects in the anterior half require an additional venous graft. The defect was shown to be significantly affecting the mechanical properties of the mandible (P value 0.0204). The animal was able to feed on soft diet from the 3rd postoperative day and returned to normal diet within a week. The mandible did not break during the period of follow up (2 months). CONCLUSIONS Our model introduces the concept of axial vascularization of mandibular constructs. This model can be used to assess bone regeneration for large bony defects in irradiated fields. This is the first study to introduce the concept of axial vascularization using the AV loop for angiogenesis in the mandibular region. Moreover, this is the first study aiming at axial vascularization of synthetic tissue engineering constructs at the site of the defect without any need for tissue transfer (in contrast to what was done previously in prefabricated flaps).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction: Mandibular reconstruction using an axially vascularized tissue-engineered construct

Correction After publication of this work [1], the authors noted that there were some corrections that should be added to the work. These corrections are done in order to modify some parts that were unfortunately missed during the original publishing procedures. The authors would like to apologize for the inconvenience. Page 2 in the Methods section under “Mechanical loading studies and design ...

متن کامل

Reconstructionof Human Mandibular Continuity Defects with Allogenic Scaffold and Autologousmarrow Mesenchymal Stem Cells

Background Mandibular continuity defects occur after tumor resection, maxillofacial injury, or osteomyelitis. Despite the current availability of a plethora of treatment modalities, bone substitutes, and various clinical adjuncts, an exact reconstructive recapitulation of large bony defects continues to be beyond reach. In this clinical pilot study, we report a novel method for reconstruction ...

متن کامل

Primate mandibular reconstruction with prefabricated, vascularized tissue-engineered bone flaps and recombinant human bone morphogenetic protein-2 implanted in situ.

Several studies have validated successful mandibular reconstruction with prefabricated tissue-engineered bone flaps and recombinant human bone morphogenetic protein-2 (rhBMP-2) implanted in situ. Whether rhBMP-2 applied with the prefabrication technique enables faster ossification of mandibular defects than rhBMP-2 applied in situ is unknown. We aimed to compare mandibular reconstruction with p...

متن کامل

Autologously generated tissue-engineered bone flaps for reconstruction of large mandibular defects in an ovine model.

The reconstruction of large craniofacial defects remains a significant clinical challenge. The complex geometry of facial bone and the lack of suitable donor tissue often hinders successful repair. One strategy to address both of these difficulties is the development of an in vivo bioreactor, where a tissue flap of suitable geometry can be orthotopically grown within the same patient requiring ...

متن کامل

Mandibular Reconstruction Using the Free Vascularized Fibula Graft: An Overview of Different Modifications

The reconstruction of the mandible is a complex procedure because various cosmetic as well as functional challenges must be addressed, including mastication and oral competence. Many surgical techniques have been described to address these challenges, including non-vascularized bone grafts, vascularized bone grafts, and approaches related to tissue engineering. This review summarizes different ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011