Myocardial salvage: retrospection, resolution, and radio waves.
نویسنده
چکیده
18. Miller DD, Johnston DL, Dragotakes D, Newell JB, Aretz T, Kantor HL, Brady TJ, Okada RD. Effect of hyperosmotic mannitol on magnetic resonance relaxation parameters in reperfused canine myocardial infarction. Magn Reson Imaging. 1989;7:79–88. 19. Schulz-Menger J, Gross M, Messroghli D, Uhlich F, Dietz R, Friedrich MG. Cardiovascular magnetic resonance of acute myocardial infarction at a very early stage. J Am Coll Cardiol. 2003;42:513–518. 20. Angelos MG, Katz-Stein A, Leasure JE. Early detection of myocardial infarction with magnetic resonance imaging in a canine model. Ann Emerg Med. 1993;22:1378–1384. 21. Li G, Xiang B, Dai G, Shaw A, Liu H, Yang B, Jackson M, Deslauriers R, Tian G. Tissue edema does not change gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA)-enhanced T1 relaxation times of viable myocardium. J Magn Reson Imaging. 2005;21:744–751. 22. Willerson JT, Scales F, Mukherjee A, Platt M, Templeton GH, Fink GS, Buja LM. Abnormal myocardial fluid retention as an early manifestation of ischemic injury. Am J Pathol. 1977;87:159–188. 23. Kim RJ, Judd RM, Chen EL, Fieno DS, Parrish TB, Lima JA. Relationship of elevated Na magnetic resonance image intensity to infarct size after acute reperfused myocardial infarction. Circulation. 1999;100:
منابع مشابه
Myocardial salvage by T2W-CMR: direct comparison to a non-destructive, high resolution, 3-dimensional ex-vivo assessment of the area at risk simultaneous with infarction
Background The amount of myocardial salvage is a critical determinant of prognosis in acute myocardial infarction (AMI). T2WCMR in combination with DE-CMR is thought to be a promising method that could presumably measure salvage. However, direct comparisons with the appropriate reference standard are limited. Additionally, even if a pathology reference standard is present, co-registration with ...
متن کاملEarly resolution of ST-segment elevation correlates with myocardial salvage assessed by Tc-99m sestamibi scintigraphy in patients with acute myocardial infarction after mechanical or thrombolytic reperfusion therapy.
BACKGROUND Early resolution of ST-segment elevation is an indicator of final infarct size and clinical outcomes. Whether this correlation is an expression of initial infarct characteristics or degree of myocardial salvage achieved with reperfusion therapy is unclear. METHODS AND RESULTS We prospectively included 243 patients with acute myocardial infarction (AMI) treated with either coronary ...
متن کاملGender differences in myocardial salvage and clinical outcome in patients with acute reperfused ST-elevation myocardial infarction
Introduction There is conflicting evidence regarding gender-based differences in outcomes in patients after myocardial infarction. Recently, a study demonstrated greater myocardial salvage assessed with SPECT imaging in women than in men. However, SPECT imaging has several limitations including its low spatial resolution particularly of subendocardial infarcts and as a result cardiac magnetic r...
متن کاملUsefulness of the presenting electrocardiogram in predicting myocardial salvage with thrombolytic therapy in patients with a first acute myocardial infarction.
AIMS Patients with Q waves and T-wave inversion are generally at a later stage of the infarction process than patients without these changes. Our aim was to investigate whether a single assessment of electrocardiographic parameters at presentation would predict the proportion of myocardium salvageable by thrombolytic therapy. METHODS AND RESULTS Electrocardiographic algorithms to calculate th...
متن کاملThe Effect of Radio Waves on the Quality and Safety of Wearable Sensors in Healthcare
The industrial Internet of Things (IoT) is aiming to interconnect humans, machines, materials, processes and services in a network. Wireless Sensor Network (WSN) comprises the less power consuming, light weight and effective Sensor Nodes (SNs) for higher network performance. Radio Frequency Identification (RFID) and sensor networks are both wireless technologies that provide limitless future po...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 113 15 شماره
صفحات -
تاریخ انتشار 2006