Direct comparison of the BD ProbeTec ET system with in-house LightCycler PCR assays for detection of Chlamydia trachomatis and Neisseria gonorrhoeae from clinical specimens.

نویسندگان

  • Michael G Koenig
  • Sandra L Kosha
  • Brandon L Doty
  • David G Heath
چکیده

The commercial BD ProbeTec ET (BDPT) system for the detection of Neisseria gonorrhoeae and Chlamydia trachomatis from clinical specimens was compared with our in-house LightCycler real-time PCR (LC-PCR) assays. Specimens initially positive by the BDPT system were retested by our LC-PCR assays. Our results for C. trachomatis testing indicate a 91.2% agreement when the results of 114 clinical specimens, initially positive by BDPT over a wide range of method-other-than-acceleration (MOTA) scores, were retested by our LC-PCR assay. The agreement between the two systems improved to 96% when only MOTA scores of >30,000 were retested by the LC-PCR assay. The overall agreement between the two systems for Neisseria gonorrhoeae detection from 155 clinical specimens was only 77.4%, with agreement particularly low (24.1%) for MOTA scores ranging from 2,000 to 19,999. Repeat testing of specimens with the BDPT only closely correlated with that seen by others demonstrating that reproducibility of the BDPT system for specimens initially within the MOTA score range from 2,000 to 9,999 is problematic, especially for Neisseria gonorrhoeae testing. With our study, we proposed an algorithm for C. trachomatis and N. gonorrhoeae testing which involves screening with the BDPT system followed by selective use of our in-house LC-PCR assays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Genital and extra-genital screening for gonorrhoea using the BD Probetec ET system with an in-house PCR method targeting the porA pseudogene as confirmatory test.

Diagnosing gonorrhoea from extra-genital as well as genital sites is important in managing this sexually transmitted disease. In this study we evaluated a screening procedure for Neisseria gonorrhoeae (GC) from all sample sites in a low-prevalence setting. A total of 69,252 specimens submitted for Chlamydia trachomatis testing were also examined for GC on the BD Viper™ platform using the BD Pro...

متن کامل

Evaluation of three automated nucleic acid amplification systems for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in first-void urine specimens.

A total of 500 first-void urine specimens were tested for the presence of Chlamydia trachomatis and Neisseria gonorrhoeae nucleic acids using ProbeTec ET reagents on a Viper platform (BD Diagnostics, Mississauga, Ontario, Canada), Aptima Combo 2 reagents on a Tigris platform (Gen-Probe, Inc., San Diego, CA), and Abbott RealTime CT/NG reagents on an m2000 platform (Abbott Molecular Diagnostics, ...

متن کامل

Performance of the Abbott RealTime CT/NG for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

A multicenter clinical study was conducted to evaluate the performance characteristics of the Abbott RealTime CT/NG assay, a multiplex real-time PCR assay, for simultaneous detection of Chlamydia trachomatis and Neisseria gonorrhoeae. The specimens were collected from a total of 3,832 male and female subjects at 16 geographically diverse sites. Specimens included male and female urine samples, ...

متن کامل

A two-site analytical evaluation of the BD Viper System with XTR Technology in Nonextracted Mode and Extracted Mode with seeded simulated specimens.

The BD ProbeTec CT Q(x) Amplified DNA Assay and the BD ProbeTec GC Q(x) Amplified DNA Assay (both BD Diagnostics, Sparks, MD) represent two new assays developed for use with the BD Viper System with XTR Technology (BD Diagnostics). These assays were built on the foundation of the former BD ProbeTec ET assays (BD Diagnostics) and its accompanying instrumentation. The study described below compar...

متن کامل

Comparison of the BD Viper System with XTR Technology to the Gen-Probe APTIMA COMBO 2 Assay using the TIGRIS DTS system for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae in urine specimens.

BACKGROUND Performances of the BD ProbeTec Chlamydia trachomatis (CT)/Neisseria Gonorrhoeae (GC) Q(x) Amplified DNA Assay reagents on a BD Viper System with XTR Technology and APTIMA COMBO 2 Assay reagents on a TIGRIS DTS platform, for detection of both CT and GC were compared. METHODS A total of 1018 first-void urine specimens were tested for the presence of CT and GC DNA using the 2 assays....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 42 12  شماره 

صفحات  -

تاریخ انتشار 2004