An investigation of the retinal nerve fibre layer in progressive multiple sclerosis using optical coherence tomography.

نویسندگان

  • Andrew P D Henderson
  • S Anand Trip
  • Patricio G Schlottmann
  • Daniel R Altmann
  • David F Garway-Heath
  • Gordon T Plant
  • David H Miller
چکیده

Axonal loss is thought to be the predominant cause of disability in progressive multiple sclerosis (MS). The retinal nerve fibre layer (RNFL) is composed largely of unmyelinated axons of retinal ganglion cells, and is accessible to study with optical coherence tomography (OCT), giving a measure of axonal loss. OCT measures of the RNFL thickness (RNFLT) and macular volume were studied in 23 patients with primary progressive multiple sclerosis (primary progressive MS) (13 male; 10 female; mean age 52 years; median EDSS 6.0; mean disease duration 11 years), and 27 patients with secondary progressive multiple sclerosis (secondary progressive MS) (8 male; 19 female; mean age 50 years; median EDSS 6; mean disease duration 22 years). Of the patients with secondary progressive MS, 14 had clinical history of optic neuritis (ON) in a single eye; the remaining patients had not had ON. Twenty healthy controls (11 male; 9 female; mean age 46 years) had RNFLT and macular volume studied. Of the patients' eyes not previously affected by ON, both the mean RNFL thickness and macular volume were reduced when compared with control values. The mean RNFL thickness and macular volume were significantly reduced in secondary progressive MS, but not in primary progressive MS when compared with control RNFL thickness and macular volume. RNFL loss was most evident in the temporal quadrant, where significant reduction was seen in primary progressive MS versus controls and in secondary versus primary progressive MS. There were significant correlations of decreased RNFLT and macular volume with measures of visual acuity, low contrast visual acuity and visual field mean deviation in the MS patients. There are significant global reductions in RNFLT and macular volume in the eyes of secondary progressive MS patients not previously affected by ON, but not in primary progressive MS patients, compared with controls. This may indicate a difference in the extent of the pathological processes that cause axonal loss in the retina, and by inference the optic nerve, in secondary progressive MS and primary progressive MS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical Coherence Tomography and Corpus Callosum Index in Cognitive Assessment of Multiple Sclerosis Patients

Background: Multiple Sclerosis (MS) is a neurodegenerative disease of central nervous system. Different approaches have been developed to study MS progression and cognitive dysfunction as the major symptom of the disease. The current study compared Optical Coherence Tomography (OCT) and Corpus Callosum Index (CCI) for the early evaluation of cognitive dysfunction in MS patients.  Objectives: T...

متن کامل

Primary retinal pathology in multiple sclerosis as detected by optical coherence tomography.

Optical coherence tomography studies in multiple sclerosis have primarily focused on evaluation of the retinal nerve fibre layer. The aetiology of retinal changes in multiple sclerosis is thought to be secondary to optic nerve demyelination. The objective of this study was to use optical coherence tomography to determine if a subset of patients with multiple sclerosis exhibit primary retinal ne...

متن کامل

A systematic review and meta–analysis of optical coherence tomography in multiple sclerosis

Optical coherence tomography (OCT) is a new method potentially applicable for the analysis of neurodegeneration in multiple sclerosis (MS) by capturing thinning of the retinal nerve fibre layer (RNFL). Metaanalyses of time domain OCT (TDOCT) data demonstrates RNFL thinning of 20 μm (95%CI 18-23, n=2063, p¡0.00001) following MS optic neuritis (MSON) and μm (95%CI 6-9, n=3154, p¡0.00001) in MS wi...

متن کامل

The association between retinal nerve fibre layer thickness and N-acetyl aspartate levels in multiple sclerosis brain normal-appearing white matter: a longitudinal study using magnetic resonance spectroscopy and optical coherence tomography.

BACKGROUND AND PURPOSE N-acetyl aspartate (NAA) assessed using proton magnetic resonance spectroscopy (1 H MRS) has a high pathological specificity for axonal density. Retinal nerve fibre layer thickness (RNFLT) measured by using optical coherence tomography is increasingly used as a surrogate marker of neurodegeneration in multiple sclerosis (MS). Our aim was to investigate the relation betwee...

متن کامل

Clinical Applications of Optical Coherence Tomography in Ophthalmology

Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases.  Furtherm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brain : a journal of neurology

دوره 131 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2008