Rapid pneumatic and Mackay-Marg applanation tonometry
نویسنده
چکیده
Glaucoma is usually considered to be adequately controlled when Goldmann applanation readings are below 22 mmHg. It is, however, now known that the intraocular pressure increases to a varying degree when the patient changes his posture from sitting to a recumbent position (Galin, McIvor, and Magruder, I963; Roberts and Rogers, I964; Hetland-Eriksen, Ig66a; Inglima, I966; Tarkkanen and Leikola, I967; Langham and McCarthy, I968; Anderson and Grant, 1973). Hetland-Eriksen (I966a, b) stated that the increase in intraocular pressure when in a recumbent position is in some way directly proportional to the initial intraocular pressure; this complicates our dependence on Goldmann tonometry as that procedure is performed routinely only in the sitting position. The present study, as well as making a clinical evaluation of the Mackay-Marg tonometer and the pneumatonograph, assesses the relationship of various postures to intraocular pressure in normal and glaucomatous eyes. The study was conducted using two of the more modem rapid applanation tonometers: the pneumatonograph (PTG)* and the Mackay-Marg electric tonometert as both are easily portable and continuously monitor the pressure on graph paper, and in addition, they can be used in any posture with equal ease and precision. Neither do they require the magnification or illumination of a slit-lamp nor the use of fluorescein, -as is essential in Goldmann tonometry. The pneumatonograph (Jain and Marmion, I976) and the Mackay-Marg (Kaufman, Wind, and Waltman, 1970) can be used to record exact pressures in cases of ectatic corneas or postkeratoplasty (Irvine and Kaufman, I969) as it is not imperative to apply the tip of the probe to the centre of the cornea in either procedure. The correlation of the PTG (Jain and Marmion,
منابع مشابه
Rapid pneumatic and Mackey-Marg applanation tonometry to evaluate the postural effect on intraocular pressure.
A postural study was conducted in three separate groups of subjects. The first group comprised 20 women volunteers with an average age of 20-75 years. In this group, the study was conducted by the pneumatonograph only. Mean pressure recorded was 15-65 +/- 0-25 mmHg and there was an average rise of 1-4 mmHg in supine posture. Groups 2 and 3 comprised 151 non-glaucomatous and 108 glaucomatous eye...
متن کاملApplanation Tonometry and Ophthalmoscopy of the Vervet Monkey (cercopithecus Ethiops) in Phencyclidine Catalepsia.
Phencyclidine, 1 to 1.2 mg. per kilogram body weight, is recommended for examination of the eyes in untamed monkeys. Applanation tonometry with the Mackay-Marg machine was performed in 109 vervets (Cercopithecus ethiops), mainly old males, contributing a total of 208 eyes without signs of present or past inflammation or trauma. A mean pressure of 17.7 mm. Hg was found. The detailed distribution...
متن کاملPassive radiotelemetry of intraocular pressure in vivo: calibration and validation of continual scleral guard-ring applanation transensors in the dog and rabbit.
Continual monitoring of intraocular pressure (IOP) by passive radiotelemetry, with a miniature scleral applanating device, mounted in a haptic contact lens (applanating transensor) is reported in the rabbit and dog. Several prototype transensors were calibrated in vivo in the rabbit and dog; a consistent linear output was obtained for each eye, although reproducibility of the slope between eyes...
متن کاملEvaluation of the basic validity and clinical usefulness of the Mackay-Marg tonometer.
The present form of the Mackay-Marg tonometer consists of a 1.5 mm. diameter fat-based plunger mounted essentially flush with a flat footplate. The rubber mounting of the plunger acts as a stiff spring. Pressure measurements are derived from intraocular pressure acting through the flattened cornea against the plunger and causing microplunger movements. It has been shown that the response of thi...
متن کاملConstant-area applanation tonography.
A tonography device, based on the MacKay-Marg tonometer, has been constructed which will applanate the cornea to a preselected area of 5.0 to 6.0 mm diameter and maintain that applanation area. The pressure decrease with time should resemble the pressure decrease following bolus injection of fluid into the eye. In most cases the pressure decreased in a linear slope, abruptly terminating in a pr...
متن کامل