Ambulatory care of patients with left ventricular assist devices.
نویسندگان
چکیده
BACKGROUND Left ventricular assist devices (LVAD) have revolutionized the treatment of patients with acute and chronic heart failure as they provide a high quality of life. We report on our experience with patients receiving ambulatory care after LVAD implantation. METHODS AND RESULTS Since July 1995, 46 patients with a mean age of 45+/-11 years underwent implantation of an electrically driven LVAD with portable controller and batteries. Sixteen (35%) patients bridged >30 days were treated in part on an outpatient basis. After LVAD implantation, they were treated in the hospital for 86+/-32 days (range 40 to 153 days). Afterward, they received ambulatory care for 74+/-76 days (range 2 to 301 days, total experience 1206 days). In 13 cases, the outpatient treatment was interrupted by 1.7+/-1.7 readmissions, for a total of 32+/-42 days (median 19 days). Reasons for readmission included systemic or drive line infections (incidence 0.0066 per outpatient day), suspected or true thromboembolic events (incidence 0.0066 per outpatient day), and suspected malfunction of the LVAD. One patient supported as alternative to transplantation died after cerebral bleeding after 244 days, 1 patient with a history of acute myocarditis had ventricular fibrillation during LVAD assist while being at home for 177 days and died in a low output state, 10 patients were given transplantation after a mean support interval of 206+/-88 days, and 4 patients currently await heart transplantation. CONCLUSIONS Outpatient treatment after LVAD implantation is feasible, and severe complications are uncommon.
منابع مشابه
Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملTo ventricular assist devices or not: When is implantation of a ventricular assist device appropriate in advanced ambulatory heart failure?
Advanced heart failure has been traditionally treated via either heart transplantation, continuous inotropes, consideration for hospice and more recently via left ventricular assist devices (LVAD). Heart transplantation has been limited by organ availability and the futility of other options has thrust LVAD therapy into the mainstream of therapy for end stage heart failure. Improvements in tech...
متن کاملEthical challenges with the left ventricular assist device as a destination therapy
The left ventricular assist device was originally designed to be surgically implanted as a bridge to transplantation for patients with chronic end-stage heart failure. On the basis of the REMATCH trial, the US Food and Drug Administration and the US Centers for Medicare & Medicaid Services approved permanent implantation of the left ventricular assist device as a destination therapy in Medicare...
متن کاملSupervised exercise training versus usual care in ambulatory patients with left ventricular assist devices: A systematic review
Implantation of left ventricular assist devices (LVAD) has increased because of improved safety profile and limited availability of heart transplantation. Although supervised exercise training (ET) programs are known to improve exercise capacity and quality of life (QoL) in heart failure (HF) patients, similar data is inconclusive in LVAD patients. Thus, we performed a systematic review on stud...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 100 19 Suppl شماره
صفحات -
تاریخ انتشار 1999