Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study

نویسندگان

  • Yigang Pei
  • Fang Li
  • Hao Shen
  • Xueying Long
  • Hui Liu
  • Xiaoyi Wang
  • Jinkang Liu
  • Wenzheng Li
چکیده

OBJECTIVE To determine whether an optimal blood suppression inversion time (BSP TI) can boost arterial visibility and whether the optimal BSP TI is related to breathing rate (BR) and heart rate (HR) for hypertension subjects in spatial labeling with multiple inversion pulses (SLEEK). MATERIALS AND METHODS This prospective study included 10 volunteers and 93 consecutive hypertension patients who had undergone SLEEK at 1.5T MRI system. Firstly, suitable BSP TIs for displaying clearly renal artery were determined in 10 volunteers. Secondly, non-contrast enhanced magnetic resonance angiography with the suitable BSP TIs were performed on those hypertension patients. Then, renal artery was evaluated and an optimal BSP TI to increase arterial visibility was determined for each patient. Patients' BRs and HRs were recorded and their relationships with the optimal BSP TI were analyzed. RESULTS The optimal BSP TI was negatively correlated with BR (r1 = -0.536, P1 < 0.001; and r2 = -0.535, P2 < 0.001) and HR (r1 = -0.432, P1 = 0.001; and r2 = -0.419, P2 = 0.001) for 2 readers (κ = 0.93). For improving renal arterial visibility, BSP TI = 800 ms could be applied as the optimal BSP TI when the 95% confidence interval were 17-19/min (BR1) and 74-82 bpm (HR1) for reader#1 and 17-19/min (BR2) and 74-83 bpm (HR2) for reader#2; BSP TI = 1100 ms while 14-15/min (BR1, 2) and 71-76 bpm (HR1, 2) for both readers; and BSP TI = 1400 ms when 13-16/min (BR1) and 63-68 bpm (HR1) for reader#1 and 14-15/min (BR2) and 64-70 bpm (HR2) for reader#2. CONCLUSION In SLEEK, BSP TI is affected by patients' BRs and HRs. Adopting the optimal BSP TI based on BR and HR can improve the renal arterial visibility and consequently the working efficiency.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Post-contrast non-selective double inversion recovery imaging of the coronary arteries in patients with coronary allograft vasculopathy

Introduction The uptake of gadolinium contrast agent in coronary walls may indicate metabolically-active atherosclerosis (Maintz et al, 2006 ) and therefore be useful in the setting of coronary allograft vasculopathy (CAV). The interpretation of inversion recovery (IR) images can be hampered by signal from tissues with longer T1 times (particularly the myocardium) as tissue suppression is T1 de...

متن کامل

Corticomedullary differentiation of the kidney: evaluation with noncontrast-enhanced steady-state free precession (SSFP) MRI with time-spatial labeling inversion pulse (time-SLIP).

PURPOSE To assess whether noncontrast-enhanced steady-state free precession (SSFP) magnetic resonance imaging (MRI) with time-spatial labeling inversion pulse (Time-SLIP) can improve the visibility of corticomedullary differentiation of the normal kidney. MATERIALS AND METHODS A series of noncontrast-enhanced SSFP MRI with Time-SLIP were performed in 20 patients by using various inversion tim...

متن کامل

Continuous Arterial Spin Labeling by a Separate Neck Coil with Inversion-Recovery Suppression of Static Tissue Signals (ir- cASL)

INTRODUCTION Arterial spin labeling (ASL) technique has been widely used to measure cerebral blood flow (CBF) in animals and humans. This approach uses “pair-wise” subtraction of alternate images taken with labeled and non-labeled conditions to obtain a difference signal that arises only from inflowing “labeling” water. Although the static tissue signal from static brain water is subtracted out...

متن کامل

The effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence

  Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...

متن کامل

Arterial Spin Labeling Angiography without the Need of Subtraction using a Triple Inversion Recovery Prepulse

INTRODUCTION: Arterial Spin Labeling (ASL) is a well-known technique for the non-invasive acquisition of angiograms without the need of a contrast agent [1][2]. ASL angiography is still clinically underused because of several challenges [3]: ASL requires two acquisitions (labeled and non labeled dataset) thereby doubling scan time. The need of subtraction increases the sensitivity to spatial mi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016