Containment of microbial aerosols in a microbiological safety cabinet.

نویسندگان

  • M S Barbeito
  • L A Taylor
چکیده

A microbiological safety cabinet was evaluated to determine conditions under which microorganisms might escape. Tests were conducted under three cabinet-closure conditions, various airflow velocities, and different laboratory operations, with 10(5), 1.1 x 10(5), and 10(6) microorganisms per cubic foot of cabinet space released per min for 5 min. The data revealed that (i) escape of a human infectious dose is possible when the cabinet is used with the glove panel off; (ii) the number of organisms that escaped from the cabinet increased with a decrease in air velocity; and (iii) an increase in the number of laboratory operations resulted in an increase in the number of organisms that escaped. Thus, when the glove panel was off, the cabinet was only safe for operations that released a small number of microorganisms into the cabinet, whereas the cabinet was safe for operations of significantly greater hazard when used with the glove panel on but with the gloves unattached.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HEPA EXHAUST FILTER IV HEPA SUPPLY FILTER I / All

A microbiological survey of the effectiveness of class II (laminar flow) 'safety' cabinets found in the UK in the last six years is recorded. Only two of the nine units tested approached the containment of aerosols achieved by a good class I (exhaust protective) cabinet. The others were potentially hazardous if used with pathogenic material. The National Sanitation Foundation and the British St...

متن کامل

Effects of airflow rates and operator activity on containment of bacterial aerosols in a class II safety cabinet.

Biological safety cabinets are frequently relied upon to provide sterile work environments in which hazardous microorganisms can be safely handled. Verification of correct airstream velocities does not, by itself, ensure that adequate protection will be achieved under all users. Instead, the concentration of microorganisms in a cabinet operator's breathing zone must be measured during typical c...

متن کامل

The Dry Aerosol Deposition Device (DADD): an instrument for depositing microbial aerosols onto surfaces.

Concerns surrounding the contamination of infrastructure and equipment with biowarfare agents have led to the development of antimicrobial surfaces/coatings that are designed to "self-sterilize." Surfaces will likely be contaminated via an aerosol exposure and thus antimicrobial efficacy measurements should also be performed using biological aerosols. Standard methods that use microbial agents ...

متن کامل

Measuring the Loss of Dexterity during Microbiological Containment Systems Use

Microbiology laboratories use containment equipment such as safety cabinets and isolators or respiratory protective equipment to protect workers against aerosol infection hazards. There is a perception amongst microbiologists that using sharps within containment equipment would increase the operator’s chance of accidental injury due to losses of dexterity within containment and so respiratory p...

متن کامل

Measuring the Loss of Dexterity during Microbiological

Microbiology laboratories use containment equipment such as safety cabinets and isolators or respiratory protective equipment to protect workers against aerosol infection hazards. There is a perception amongst microbiologists that using sharps within containment equipment would increase the operator’s chance of accidental injury due to losses of dexterity within containment and so respiratory p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied microbiology

دوره 16 8  شماره 

صفحات  -

تاریخ انتشار 1968