Effect of N2O on sevoflurane vaporizer settings during minimal- and low-flow anesthesia.
نویسندگان
چکیده
BACKGROUND Uptake of a second gas of a delivered gas mixture decreases the amount of carrier gas and potent inhaled anesthetic leaving the circle system through the pop-off valve. The authors hypothesized that the vaporizer settings required to maintain constant end-expired sevoflurane concentration (Etsevo) during minimal-flow anesthesia (MFA, fresh gas flow of 0.5 l/min) or low-flow anesthesia (LFA, fresh gas flow of 1 l/min) would be lower when sevoflurane is used in oxygen-nitrous oxide than in oxygen. METHODS Fifty-six patients receiving general anesthesia were randomly assigned to one of four groups (n = 14 each), depending on the carrier gas and fresh gas flow used: group Ox.5 l (oxygen, MFA), group NOx.5 l (oxygen-nitrous oxide, MFA after 10 min high fresh gas flow), group Ox1 l (oxygen, LFA), and group NOx1 l (oxygen-nitrous oxide, LFA after 10 min high fresh gas flow). The vaporizer dial settings required to maintain Etsevo at 1.3% were compared between groups. RESULTS Vaporizer settings were higher in group Ox.5 l than in groups NOx.5 l, Ox1 l, and NOx1 l; vaporizer settings were higher in group NOx.5 l than in group NOx1 l between 23 and 47 min, and vaporizer settings did not differ between groups Ox1 l and NOx1 l. CONCLUSIONS When using oxygen-nitrous oxide as the carrier gas, less gas and vapor are wasted through the pop-off valve than when 100% oxygen is used. During MFA with an oxygen-nitrous oxide mixture, when almost all of the delivered oxygen and nitrous oxide is taken up by the patient, the vaporizer dial setting required to maintain a constant Etsevo is lower than when 100% oxygen is used. With higher fresh gas flows (LFA), this effect of nitrous oxide becomes insignificant, presumably because the proportion of excess gas leaving the pop-off valve relative to the amount taken up by the patient increases. However, other unexplored factors affecting gas kinetics in a circle system may contribute to our observations.
منابع مشابه
Predictive accuracy of a model of volatile anesthetic uptake.
UNLABELLED A computer program that models anesthetic uptake and distribution has been in use in our department for 20 yr as a teaching tool. New anesthesia machines that electronically measure fresh gas flow rates and vaporizer settings allowed us to assess the performance of this model during clinical anesthesia. Gas flow, vaporizer settings, and end-tidal concentrations were collected from th...
متن کاملThe effect of a model-based predictive display on the control of end-tidal sevoflurane concentrations during low-flow anesthesia.
We have shown that a multicompartment model accurately predicts end-tidal (ET) sevoflurane (sevo) and isoflurane concentrations. The model has been adapted to use real-time fresh gas flow and vaporizer settings to display a 10-min prediction of ET sevo concentrations. In this study, we evaluated the effect of the predictive display on the speed and accuracy of changes in ET sevo by the anesthes...
متن کاملGlobal warming potential of inhaled anesthetics: application to clinical use.
BACKGROUND Inhaled anesthetics are recognized greenhouse gases. Calculating their relative impact during common clinical usage will allow comparison to each other and to carbon dioxide emissions in general. METHODS We determined infrared absorption cross-sections for sevoflurane and isoflurane. Twenty-year global warming potential (GWP(20)) values for desflurane, sevoflurane, and isoflurane w...
متن کاملInteraction between nitrous oxide, sevoflurane, and opioids: a response surface approach.
BACKGROUND The interaction of sevoflurane and opioids can be described by response surface modeling using the hierarchical model. We expanded this for combined administration of sevoflurane, opioids, and 66 vol.% nitrous oxide (N2O), using historical data on the motor and hemodynamic responsiveness to incision, the minimal alveolar concentration, and minimal alveolar concentration to block auto...
متن کاملEffects of sevoflurane, propofol, and adjunct nitrous oxide on regional cerebral blood flow, oxygen consumption, and blood volume in humans.
BACKGROUND Anesthetic agents, especially volatile anesthetics and nitrous oxide (N2O), are suspected to perturb cerebral homeostasis and vascular reactivity. The authors quantified the effects of sevoflurane and propofol as sole anesthetics and in combination with N2O on regional cerebral blood flow (rCBF), metabolic rate of oxygen (rCMRO2), and blood volume (rCBV) in the living human brain usi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 97 2 شماره
صفحات -
تاریخ انتشار 2002