A biomechanical comparison study of a modern fibular nail and distal fibular locking plate in AO/OTA 44C2 ankle fractures
نویسندگان
چکیده
BACKGROUND A lateral approach with open reduction and internal fixation with a plate is a very effective technique for the majority of distal fibular fractures. However, this open approach for ankle fixation may be complicated by wound dehiscence and infection, especially in high-risk patients. An alternative to plating is an intramedullary implant, which allows maintenance of length, alignment, and rotation and which allows for decreased soft tissue dissection. While there has been clinical data suggesting favorable short-term outcomes with these implants, there is no current biomechanical literature investigating this technology in this particular fracture pattern. This study sought to biomechanically compare an emerging technology with an established method of fixation for distal fibular fractures that traditionally require an extensive exposure. METHODS Ten matched cadaveric pairs from the proximal tibia to the foot were prepared to simulate an Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) 44C2 ankle fracture and randomized to fixation with a distal fibular locking plate or intramedullary fibular rod. A constant 700-N axial load was applied, and all specimens underwent testing for external rotation stiffness, external rotation cyclic loading, and torque to failure. The syndesmotic diastasis, stiffness, torque to failure, angle at failure, and mode of failure were obtained from each specimen. RESULTS There was no significant difference in syndesmotic diastasis during cyclic loading or at maximal external rotation between the rod and plate groups. Post-cycle external rotation stiffness across the syndesmosis was significantly higher for the locking plate than the fibular rod. There was no significant difference between the rod and plate in torque at failure or external rotation angle. The majority of specimens had failure at the syndesmotic screw. CONCLUSIONS In the present cadaveric study of an AO/OTA 44C2 ankle fracture, a modern fibular rod demonstrated less external rotation stiffness while maintaining the syndesmotic diastasis to within acceptable tolerances and having similar failure characteristics.
منابع مشابه
Comparison of lateral locking plate and antiglide plate for fixation of distal fibular fractures in osteoporotic bone: a biomechanical study.
OBJECTIVES The purpose of this study was to compare the biomechanical properties of posterolateral antiglide plating and lateral locked plating for fixation of displaced short oblique fractures of the fibula in osteoporotic bone. METHODS Short oblique fractures of the distal fibula at the level of the syndesmosis were simulated with a fibular osteotomy and ligamentous sectioning in 18 paired ...
متن کاملOutcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia
Background: Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteo...
متن کاملA locking contoured plate for distal fibular fractures: mechanical evaluation in an osteoporotic bone model using screws of different length.
Osteoporotic bone with poor mechanical capacity provides limited stability after fixation of ankle fractures. Stabilization with an implant providing increased fixation strength in osteoporotic bone could reduce failure rates of fixation and allow a more functional treatment. The purpose of this study was to evaluate a locking contoured plate for fixation of distal fibular fractures in comparis...
متن کاملFixation of distal fibular fractures: A biomechanical study of plate fixation techniques.
Ankle fractures are complex injuries with variable prognoses that depend upon many factors. The aim of the treatment is to restore the ankle joint biomechanical stability with maximum range of motion. Most ankle fractures are fibular fractures, which have a typical oblique fracture line in the distal fibula located in the area of the tibiofibular syndesmosis. The aim of this study was to simula...
متن کاملHindfoot Valgus following Interlocking Nail Treatment for Tibial Diaphysis Fractures: Can the Fibula Be Neglected?
Purpose. We evaluated whether intramedullary nail fixation for tibial diaphysis fractures with concomitant fibula fractures (except at the distal one-third level) managed conservatively with an associated fibula fracture resulted in ankle deformity and assessed the impact of the ankle deformity on lower extremity function. Methods. Sixty middle one-third tibial shaft fractures with associated f...
متن کامل