Evaluating "eee" phonation in multidetector CT of the neck.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Since the advent of pharyngography, "eee" phonation has been used to distend the airway during imaging. When imaging shifted to axial CT, "eee" phonation was used to delineate mucosal anatomy better. However, because patients could not phonate for the entire examination (which could take several minutes), the technique was only useful during supplemental imaging, performed after the primary acquisition through the neck. The supplemental images covered a limited area (usually the larynx or supraglottis) and, therefore, could be obtained while patients phonated. Imaging of the neck has now shifted to multidetector CT (MDCT). With a 64-detector MDCT, the entire neck can be imaged in 8 seconds. We evaluated whether "eee" phonation could be used during the entire acquisition through the neck without degrading image quality. MATERIALS AND METHODS Forty-eight patients who performed "eee" phonation during a CT examination of the neck were compared with 96 patients scanned following a breath-hold command. All patients were scanned on the same 64-detector MDCT scanner after intravenous contrast administration. Images were acquired at a 2-mm section thickness and reconstructed at 1-mm intervals. All scanning times ranged from 5 to 7 seconds. Studies were evaluated separately by 2 neuroradiologists for image degradation due to motion. Statistical analysis was performed by using the proportional odds ratio. RESULTS We found no significant difference in motion during phonation compared with the breath-hold technique. CONCLUSIONS Our results indicate that "eee" phonation can be performed during an entire image acquisition through the neck, when performed with the speed of the 64-detector scanner, without increasing motion.
منابع مشابه
Staging of laryngeal cancer using 64-channel multidetector row CT: comparison of standard neck CT with dedicated breath-maneuver laryngeal CT.
BACKGROUND AND PURPOSE With a 64-channel multidetector row CT, imaging acquisition during speech, swallowing, or phonation has become feasible. However, the actual benefit of these additional focused images should be critically evaluated with respect to radiation dose. The purpose of this study was to determine if dedicated laryngeal CT using breath-holding and straw-blowing improved the accura...
متن کاملComparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism
Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...
متن کاملSinonasal Anatomical Variations: A Multidetector Computed Tomographic Study
Background and Aim: The paranasal sinuses are known for their complex anatomy and significant difference in size and shape. This study aimed to determine the prevalence of anatomical variations of the paranasal sinuses in computed tomography (CT). Materials and Methods: In this cross-sectional study, patients over 18 years of age, who had undergone CT imaging in a private clinic, were screened...
متن کاملChronic sphenoid sinusitis revisited: comparison of multidetector axial sections, multiplanar reconstructions, and virtual sinoscopy with endoscopic sinus surgery.
OBJECTIVES To assess the role of multidetector computed tomography (CT) and CT virtual sinoscopy in the evaluation of chronic sphenoid sinusitis and to compare the imaging findings with functional endoscopic sinus surgery. DESIGN Prospective study. SETTING Tertiary care teaching hospital. PATIENTS Thirty patients with chronic sphenoid sinusitis referred for preoperative CT. INTERVENTION...
متن کاملIschemic stroke: etiologic work-up with multidetector CT of heart and extra- and intracranial arteries.
PURPOSE To assess the potential of a single-session multidetector computed tomography (CT) protocol, as compared with established methods, for the etiologic work-up of acute ischemic stroke. MATERIALS AND METHODS Patients found to have recently experienced an ischemic stroke were recruited for this prospective study after institutional review board approval was obtained. Each patient was sche...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 30 6 شماره
صفحات -
تاریخ انتشار 2009