Perimetry Comparisons for Octopus G Top and Dynamic Programmes versus Humphrey 24-2 SITA Fast and SITA Standard Programmes
نویسندگان
چکیده
Aims: Previous comparisons of Octopus and Humphrey threshold programmes have shown differences, particularly for depth of defects. Recent developments have altered the Octopus background illumination. Thus, we sought to determine the subsequent extent of differences in results from commonly used central static programmes using Octopus and Humphrey perimeters. Study Design: Diagnostic accuracy study. Place and Duration of Study: Department of Ophthalmology, Warrington and Halton Hospitals NHS Foundation Trust, between June 2009 and July 2012. Methodology: We utilised Octopus G-TOP or G-dynamic programmes and Humphrey 24-2 SITA fast or standard programmes. Poor reliability was taken as errors >25%. Comparison was made for global indices (mean sensitivity, mean deviation, pattern standard deviation/loss variance), test duration from each perimeter using unpaired t tests, and Bland Altman plots for correlation of individual differences between perimeters. Clinical agreement for presence/absence of visual field loss was determined by Original Research Article Rowe et al.; OR, Article no. OR.2014.004 25 independent assessment of results by two authors (kappa test). Results: Eighty patients (159 eyes) were recruited. 38 eyes were excluded due to poor reliability. 34 patients (55 eyes) underwent fast static visual field assessment: 17 males and 17 females with a mean age of 63 years (SD 14). 38 patients (64 eyes) underwent standard static visual field assessment: 18 males and 20 females with a mean age of 65 years (SD 13). For both full and fast perimetry, both perimeters showed good agreement for inter observer comparison (K=0.5-0.6). SITA standard perimetry showed a higher mean sensitivity value (+2.5dB±1.0) and SITA fast perimetry showed a higher mean sensitivity value (+3.4dB±1.1) than Octopus values. Bland-Altman analysis showed increasing variability with increasing severity of defect indicating a lack of correlation for moderate to severe visual field results. Conclusions: Visual field results were comparable for mild defects. Octopus perimetry continues to show greater defect size where there is more extensive visual field loss relating to the different strategies used by both perimeters.
منابع مشابه
Different strategies for Humphrey automated perimetry: FASTPAC, SITA standard and SITA fast in normal subjects and glaucoma patients.
PURPOSE To evaluate the influence on examination time and test quality of the recently introduced SITA strategies of the Humphrey Field Analyzer. METHODS The sample consisted of 41 subjects (19 normal subjects and 22 glaucoma patients), all experienced in automated perimetry, ranging in age from 24 to 83 years. One eye of each patient was examined with the HC30-2 program using the FASTPAC (FP...
متن کاملThe SITA perimetric threshold algorithms in glaucoma.
PURPOSE To determine the within-visit between-algorithm and the within-algorithm between-visit differences in sensitivity for the SITA Standard, SITA Fast, FASTPAC, and Full Threshold algorithms in stable primary open angle glaucoma. METHODS One designated eye from each of 29 patients (age 67.3 +/- 10.2 years; mean +/- SD) experienced in automated perimetry was examined with the four algorith...
متن کاملBetween-algorithm, between-individual differences in normal perimetric sensitivity: full threshold, FASTPAC, and SITA. Swedish Interactive Threshold algorithm.
PURPOSE To determine the between-algorithm differences in perimetric sensitivity for the Swedish Interactive Threshold algorithm (SITA) Standard, SITA Fast, FASTPAC, and Full Threshold algorithms; to determine the between-subject, between-algorithm differences in the magnitude of the normal variation in sensitivity. METHODS The sample comprised 50 normal subjects (mean age, 52.9 +/- 18.5 year...
متن کاملDetection of central visual field defects in early glaucomatous eyes: Comparison of Humphrey and Octopus perimetry
PURPOSE To compare the detection rate of central visual field defect (CVFD) between the 30-degree Octopus G1 program (Dynamic strategy) and the HFA 10-2 SITA-Standard test in early glaucoma eyes not showing any CVFD on the HFA 24-2 SITA-Standard test. METHODS One eye of 41 early glaucoma patients without CVFD in the central 10° on HFA 24-2 test was tested with both the HFA 10-2 test and the O...
متن کاملAssessment of retinal sensitivity using a time-saving strategy in normal individuals
BACKGROUND The purpose of this study was to compare retinal sensitivities in normal individuals obtained using the Swedish Interactive Threshold Algorithm Standard (SITA-S) on the Humphrey field analyzer with those obtained using the Dynamic strategy on the Octopus. METHODS Prior to visual field examinations, the background luminance, stimulus size, and exposure time with the Octopus 101 were...