Intensity-modulated radiation therapy dose prescription, recording, and delivery: patterns of variability among institutions and treatment planning systems.

نویسندگان

  • Indra J Das
  • Chee-Wai Cheng
  • Kashmiri L Chopra
  • Raj K Mitra
  • Shiv P Srivastava
  • Eli Glatstein
چکیده

BACKGROUND Intensity-modulated radiation therapy (IMRT) is a widely accepted method for radiation treatment to provide a prescribed and uniform dose to the target volume and a minimum dose to normal tissues that is dependent on the IMRT software and the treatment machine. We examined the variation in IMRT dose prescription, treatment planning, dose recording, and dose delivery among cancer patients who were treated with different treatment planning systems at different medical institutions to assess variability in patient care. METHODS We conducted a retrospective analysis of 803 patients who were treated with IMRT between October 2004 and July 2006 for brain, head and neck, or prostate cancer at five medical institutions that used different treatment planning systems. The prescribed dose to the target volume, as recorded in the chart or as noted in the electronic data management system, was extracted for each patient. The planned dose that was delivered to the patient, as represented in the dose-volume histogram, was acquired from each treatment planning system. The actual minimum, maximum, median, and isocenter doses to the target volume were normalized to the prescribed dose and analyzed for each disease site and institution. RESULTS Of the 803 patients, 12% were treated for brain cancer, 26% for head and neck cancer, and 62% for prostate cancer. The recorded dose variability from prescription was widespread for the minimum, maximum, and isocenter doses. A total of 46% of the patients received a maximum dose that was more than 10% higher than the prescribed dose, and 63% of the patients received a dose that was more than 10% lower than the prescribed dose. At all five institutions, the prostate cancer cases had the smallest dosimetric variation and the head and neck cancer cases had the largest variation. The median dose to the target varied from the prescribed dose by +/-2% in 68% of the patients, by +/-5% in 88% of the patients, and by +/-10% in 96% of the patients. The recorded isocenter dose varied from prescription for all disease sites and treatment planning systems. CONCLUSIONS Substantial variation in the prescribed and delivered doses exists among medical institutions, raising concerns about the validity of comparing clinical outcomes for IMRT. The isocenter dose in IMRT is simply a point dose and often does not reflect the prescription dose that is specified by a selected isodose line encompassing the target volume. This study suggests the need for national and/or international guidelines for dose prescription, planning, and reporting for a meaningful clinical trial in IMRT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Quality Control of Intensity Modulated Radiation Therapy (IMRT) for ONCOR Siemens Linear Accelerators Using Film Dosimetry

Introduction Intensity Modulated Radiation Therapy (IMRT) has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various ...

متن کامل

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Surveillance on interfacility differences in dose-prescription policy of intensity-modulated radiation therapy plans for prostate cancer

Intensity-modulated radiation therapy (IMRT) has recently become popular in Japan. Prostate cancer is indisputably one of the main targets of IMRT. However, the current status and interfacility differences in dose-prescription policies for prostate IMRT are unknown. Therefore, a nationwide survey of 43 institutions that had implemented prostate IMRT was conducted by sending a questionnaire rega...

متن کامل

3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk

Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...

متن کامل

Re: Intensity-modulated radiation therapy dose prescription, recording, and delivery: patterns of variability among institutions and treatment planning systems.

The recent article by Das et al. (1) questions the validity of comparing outcome data for patients treated with intensity-modulated radiation therapy (IMRT) treatments across multiple centers because of the inherent het-erogeneity of the dose distribution. Their data supporting this assertion consist of the minimum, maximum, median, and isocenter point doses for 803 patients who were treated at...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the National Cancer Institute

دوره 100 5  شماره 

صفحات  -

تاریخ انتشار 2008