Estimate interaction timing in a large volume HgI2 detector using cathode pulse waveforms.
نویسندگان
چکیده
This paper presents experimental results on the timing resolution achieved with a 5 mm thick HgI2 detector. The timing information was derived based on the cathode pre-amplifier pulse waveform, measured using a digital oscilloscope. The times of interaction were estimated by fitting the measured pulse waveforms to pre-defined waveform models. With this approach, problems related to the conventional leading edge or constant fraction triggering, such as slow charge carrier mobility, pulse shape variation and depth-dependent detector response can be greatly reduced. As a result, we showed a 13 ns timing resolution measured using the 5 mm thick HgI2 detector and a BaF2 coincidence detector with 511 keV full energy events. In this paper, we discuss several waveform models and the results achieved using these models.
منابع مشابه
Exploring the limiting timing resolution for large volume CZT detectors with waveform analysis.
This paper presents a study for exploring the limiting timing resolution that can be achieved with a large volume 3-D position sensitive CZT detector. The interaction timing information was obtained by fitting the measured cathode waveforms to pre-defined waveform models. We compared the results from using several different waveform models. Timing resolutions, of ~9.5 ns for 511 keV full-energy...
متن کاملLarge Volume HgI2 Gamma-Ray Spectrometers
This paper demonstrates the enhanced capability of single polarity charge sensing, the 3-dimensional position sensing technique, developed at the University of Michigan and previously successfully demonstrated on CdZnTe detectors, to improve the spectroscopic performance of HgI2 and to extend its range for spectrometry to an unprecedented thickness of 10 mm. Energy resolutions of close to 1% FW...
متن کاملImpact of drift time variation on the Compton image from large-volume CdZnTe crystals
In pixelated CdZnTe detectors, multiple interaction gamma-ray events are critical because they permit Compton imaging. However, in large-volume CdZnTe crystals, the depth of multiple interaction events is often poorly reconstructed due to significant nonuniformity of electron drift velocity while the depth of single interaction events can be accurately reconstructed using signal ratios. The non...
متن کاملExperimental results from an Imarad 8]8 pixellated CZT detector
This paper reports experimental results obtained from an 8]8 pixellated CZT detector provided by Imarad Imaging Systems. Three arbitrarily selected pixels were independently tested using c rays of di!erent energies. The signals from an anode pixel and the cathode were read out simultaneously. From the observations of the pulse waveforms from both the anode pixel and the cathode, the electron-in...
متن کاملCollection of holes in thick TlBr detectors at low temperature
A 3.5 3.5 4.6 mm thick TlBr detector with pixellated Au/Cr anodes made by Radiation Monitoring Devices Inc. was studied. The detector has a planar cathode and nine anode pixels surrounded by a guard ring. The pixel pitch is 1.0 mm. Digital pulse waveforms of preamplifier outputs were recorded using a multichannel GaGe PCI digitizer board. Several experiments were carried out at 20 1C, with the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
دوره 545 1-2 شماره
صفحات -
تاریخ انتشار 2005