Surface modification of Beckman Ultra-Clear centrifuge tubes for density gradient centrifugation of lipoproteins.

نویسنده

  • L Holmquist
چکیده

A simple procedure for coating the interior surface of Beckman Ultra-Clear centrifuge tubes with polyvinyl alcohol is described. The coated tubes are wettable and allow salt solutions to gravity-feed down their sides. This modification of the tubes permits the performance of previously developed density gradient and uniform density ultracentrifugation procedures for lipoprotein fractionation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Purification of the protein crystal from Bacillus thuringiensis by zonal gradient centrifugation.

A method is described for the large-scale purification of the Bacillus thuringiensis protein crystal by zonal gradient centrifugation. NaBr gradients are employed in a Beckman J21-B centrifuge equipped with a JCF-Z rotor.

متن کامل

Atherogenic Diet-Induced Modification of the Subtraction Distribution of High Density Lipoproteins in Monkeys

High density lipoproteins (HDL) were isolated from the plasma of adult male African green monkeys fed control or atherogenic diets and were then subfractionated in a density gradient by centrifugation at 50,000 rpm, 20° C for 18 hours in the Beckman VTi50 vertical rotor. Material from the gradient was pooled into six subfractions for further analysis. With increasing density across the gradient...

متن کامل

Atherogenic diet-induced modification of the subfraction distribution of high density lipoproteins in monkeys.

High density lipoproteins (HDL) were isolated from the plasma of adult male African green monkeys fed control or atherogenic diets and were then subfractionated in a density gradient by centrifugation at 50,000 rpm, 20 degrees C for 18 hours in the Beckman VTi50 vertical rotor. Material from the gradient was pooled into six subfractions for further analysis. With increasing density across the g...

متن کامل

Advantages and limitations of density gradient ultracentrifugation in the fractionation of human serum lipoproteins: role of salts and sucrose.

Two density gradient ultracentrifugation methods, Redgrave et al. (1975. Anal. Biochem. 65: 42-49) and Nilsson et al. (1981. Anal. Biochem. 110: 342-348), currently used for the separation and analysis of plasma lipoproteins were compared with respect to their resolving power and capacity to obtain pure products as a function of time of ultracentrifugation using the same rotor (Beckman SW-40), ...

متن کامل

Sequential ultracentrifugation micromethod for separation of serum lipoproteins and assays of lipids, apolipoproteins, and lipoprotein particles.

We describe a fast sequential separation of very-low-density, low-density, and high-density lipoproteins from 400 microL of serum, using the Beckman TL100 ultracentrifuge. The cumulative centrifugation time is 9.5 h. The purity of lipoprotein fractions was verified by a gel-filtration procedure. The major contaminant is the serum albumin, which can be eliminated by a second centrifugation at th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of lipid research

دوره 23 8  شماره 

صفحات  -

تاریخ انتشار 1982