Advances in fiducial‐free image‐guidance for spinal radiosurgery with CyberKnife – a phantom study

نویسندگان

  • Christoph Fürweger
  • Christian Drexler
  • Markus Kufeld
  • Alexander Muacevic
  • Berndt Wowra
چکیده

The image-guided CyberKnife radiosurgery system is apable of tracking spinal targets without fiducial implants. Recently, a new version of this fiducial-free image guidance modality ("enhanced Xsight spine tracking") has been introduced. We assessed the accuracy of this novel technique versus its precursor in a comparative phantom study. The CyberKnife consists of a 6 MV linac on a six-axis robot and a stereoscopic kV image guidance system. An anthropomorphic head-and-neck phantom with a cervical spine section was mounted on the linac nozzle. The robotic manipulator was used to precisely move the phantom to defined positions in the CyberKnife workspace. Multiple stereoscopic images were acquired at different translational and rotational positions. The enhanced Xsight spine tracking readouts were recorded and compared to the nominal phantom position. These tests were repeated with the original Xsight spine tracking version to analyze potential differences. Enhanced Xsight spine tracking correctly reported translational offsets with an RMS error of less than 0.4 mm. Yaw and roll rotations were detected with an accuracy of 0.2°, 0.25°. Pitch offsets were slightly underestimated, with up to 0.3° for an offset of ± 2°. Nominal X (left-right) translational offsets were partially misinterpreted as roll (0.2° at a 10 mm offset). Apart from this, no correlation between rotational and translational directions was found. In comparison, the original Xsight spine tracking showed identical results for translations, but larger systematic and statistical errors for rotations. Enhanced Xsight spine tracking measurably improves precision in fiducial-free spinal radiosurgery with the CyberKnife.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fiducial-free real-time image-guided robotic radiosurgery for tumors of the sacrum/pelvis.

BACKGROUND AND PURPOSE Radiosurgery is a non-invasive treatment for many spinal tumors. Sacral radiosurgery, however, requires invasive fiducial marker insertion to target and track the tumor's position. We present preliminary clinical results and phantom accuracy measurements of sacral radiosurgery using fiducial-free alignment based on vertebral anatomy distant to tumor location. MATERIALS ...

متن کامل

CyberKnife radiosurgery for spinal neoplasms.

The role of stereotactic radiosurgery for the treatment of intracranial lesions is well established. Its use for the treatment of spinal lesions has been limited by the availability of effective target immobilization and localization technologies. Conventional external beam radiotherapy lacks the precision to allow delivery of large doses of radiation near radiosensitive structures such as the ...

متن کامل

SU-E-T-453: A Novel Daily QA System for Robotic Image Guided Radiosurgery with Variable Aperture Collimator.

PURPOSE A novel end-to-end system using a CCD camera and a scintillator based phantom that is capable of measuring the beam-by-beam delivery accuracy of Robotic Radiosurgery has been developed and reported in our previous work. This work investigates its application to end-to-end type daily QA for Robotic Radiosurgery (Cyberknife) with Variable Aperture Collimator (Iris). METHODS The phantom ...

متن کامل

Spinal radiosurgery using the synergy-S system.

Current spinal radiosurgery systems have a different workflow: the procedure is initiated with a CT scan and MRI using special high resolution protocols and immobilization devices. The targets and organs at risk are contoured, treatment is planned, and quality assurance procedures are performed. The patient then undergoes the treatment with the same immobilization device in an outpatient settin...

متن کامل

Intravascular Placement of Metallic Coils as Lung Tumor Markers for CyberKnife Stereotactic Radiation Therapy

OBJECTIVE To present our experience with placing endovascular coils in pulmonary arteries used as a fiducial marker for CyberKnife therapy and to describe the technical details and complications of the procedure. MATERIALS AND METHODS Between June 2005 and September 2013, 163 patients with primary or secondary lung malignancies, referred for fiducial placement for stereotactic radiosurgery, w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2010