Evaluation of BACTEC system for urine culture screening.

نویسندگان

  • D Colombrita
  • G Ravizzola
  • F Pirali
  • M Manni
  • N Manca
  • E Savoldi
  • A Turano
چکیده

We compared urine culturing performed by the calibrated loop method with a screening system (BACTEC). A total of 852 urine specimens were examined by both the conventional loop method and the BACTEC system. With the loop method, 193 (22.6%) urine samples were positive, whereas with the BACTEC system, 185 (21.7%) were positive (sensitivity, 96.01%). At a breakpoint of 10(4) CFU/ml, eight false-negatives were detected (sensitivity, 87.09%), and at a breakpoint of 10(5) CFU/ml, four false-negatives were observed (sensitivity, 97.6%). The specificity of the BACTEC system was 100%. We propose the BACTEC method as an effective alternative to the other growth-dependent screening tests for bacteriuria.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تشخیص بروسلوز با استفاده از سیستم کشت خون ‌ BACTECو تائید نتایج آن با PCR

Abstract: Brucellosis is one of the most common zoonotic diseases in Iran. Growth of Brucella is slow and blood cultures of these bacteria are time-consuming via classical methods. We try to evaluate BACTEC 9120 system capacity in order to detect of bacteremia due to Brucella spp and to confirm isolated bacteria by PCR. Blood culture sample of 102 suspected patients evaluated by BACTEC 9120 sys...

متن کامل

Evaluation of the MB/BacT system and comparison to the BACTEC 460 system and solid media for isolation of mycobacteria from clinical specimens.

The MB/BacT automated system is designed for the isolation of mycobacteria from clinical specimens. It utilizes a colorimetric sensor and reflected light to continuously monitor the CO2 concentration in the culture medium. We compared its performance to that of the BACTEC 12B media for the radiometric BACTEC 460 instrument and that of solid culture media. Respiratory specimens and urine samples...

متن کامل

Comparative evaluation of nonradiometric BACTEC and improved oxoid signal blood culture systems in a clinical laboratory.

The BACTEC NR660 blood culture system, which uses infrared spectroscopy to detect carbon dioxide generated by bacterial growth, was compared with the new medium formulation of the Oxoid Signal system. Two trials were conducted: a comparative study of 88 organisms in simulated blood cultures and a clinical trial of 3,321 paired patient blood culture samples. Both trials showed that overall the B...

متن کامل

Comparative Evaluation of Conventional Blood Culture with Bactec 9050 for Bacterial Isolates in Clinically Suspected Cases of Fever of Unknown Origin

Background: Patients with fever of unknown origin (FUO) are elusive and challenging clinical cases. Timely detection and identification of blood borne pathogen is one of the most important functions of microbiology laboratory. Objectives: To evaluate the efficacy of BACTEC 9050 in comparison to conventional blood culture for detection of bacterial isolates in clinically suspected cases of fever...

متن کامل

The evaluation of FASTPlaqueTB test for the rapid diagnosis of tuberculosis.

FASTPlaqueTB (Biotec Laboratories Ltd., Ipswich, UK) is a rapid test which utilizes bacteriophage amplification technology for the detection of viable Mycobacterium tuberculosis in clinical specimens. We evaluated performance of the FASTPlaqueTB test by comparing with BACTEC 460 TB culture system (Becton Dickinson Co., Maryland, USA), polymerase chain reaction (PCR) and acid fast bacilli (AFB) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 27 1  شماره 

صفحات  -

تاریخ انتشار 1989