Exact emission SPECT reconstruction with truncated transmission data.

نویسندگان

  • Gengsheng L Zeng
  • Grant T Gullberg
چکیده

UNLABELLED It is common, even with new SPECT/CT systems, that the transmission data are truncated. This paper develops a method that obtains exact attenuation correction with truncated transmission data. The emission object (e.g., the heart) is assumed to have a finite, convex support, whose emission projections are not truncated. The transmission measurements over the support are available, but may be truncated outside the support (within the torso). A novel emission data reconstruction technique combines emission projections from conjugate views; a modified version of the ML-EM algorithm is used to reconstruct emission data. The attenuation map outside the support is not needed during reconstruction. The transmission measurements through the support are used to pre-scale the emission data and to reconstruct the attenuation map within the support. The attenuation map reconstruction within the support is an interior problem in which only a biased solution can be obtained using an iterative algorithm. The bias is then corrected by identifying a soft tissue region within the support and the known attenuation coefficient values of these pixels for the soft tissue. Proof of convergence of the new algorithm is provided. Computer simulations verify the accuracy of the new method. CONCLUSIONS an exact attenuation map within the support can be obtained provided the attenuation coefficient is known at 1 pixel within the support. The method, which requires emission data over 360 degrees , provides a means to perform attenuation correction in SPECT with truncated transmission data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SPECT region of interest reconstruction with truncated transmission and emission data.

PURPOSE The aim of this article is to propose an exact SPECT region of interest (ROI) reconstruction method using truncated transmission and truncated emission data. METHODS Recently, the authors published two articles in Physics in Medicine and Biology with two results in SPECT ROI emission image reconstruction. The first result states that if the transmission data are truncated but the emis...

متن کامل

Interior SPECT- Exact and Stable ROI Reconstruction from Uniformly Attenuated Local Projections.

Single photon emission computed tomography (SPECT) is an important biomedical imaging modality. However, since gamma cameras are expensive and bulky, truncated projection data are either preferred or unavoidable. Inspired by the recent results on interior tomography in the x-ray CT field, here we present the interior SPECT approach for exact and stable reconstruction of a region of interest (RO...

متن کامل

Review of transmission scanning configurations in cardiac SPECT

The diagnostic accuracy of single photon emission computed tomography (SPECT) is profoundly influenced by attenuation phenomenon. Soft tissue attenuation degrades cardiac SPECT image quality, thereby decreasing the possibility of the detection of the lesions. A variety of correction techniques based on different assumptions have been used to reduce the impact of attenuation. Several types of sy...

متن کامل

Exact iterative reconstruction for the interior problem.

There is a trend in single photon emission computed tomography (SPECT) that small and dedicated imaging systems are becoming popular. For example, many companies are developing small dedicated cardiac SPECT systems with different designs. These dedicated systems have a smaller field of view (FOV) than a full-size clinical system. Thus data truncation has become the norm rather than the exceptio...

متن کامل

Image reconstruction in 2D SPECT with 180◦ acquisition

This work concerns 2D SPECT imaging with uniform attenuation in the activity region. In this paper, it is shown that exact and stable reconstruction does not require the data to be known over 360◦ as has been previously assumed. An angular range of 180◦ is sufficient in parallel-beam geometry. A reconstruction formula which uses only data on a half-turn is provided with implementation details. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 54 11  شماره 

صفحات  -

تاریخ انتشار 2009