Anterior Segment Intraocular Lens Edge Profiles of Currently Available Intraocular Lenses and Recent Improvements
نویسنده
چکیده
We evaluated the microstructure of the edges of currently available foldable intraocular lenses (IOLs). The methodology used assisted an IOL manufacturer (Hoya, Japan) to optimise the edge profile of its lenses. Ten designs of hydrophobic acrylic, six designs of silicone and 24 designs of hydrophilic acrylic IOLs were imaged under scanning electron microscopy (SEM), and the photographs were imported to a digital computer program. The area above the posterior–lateral edge, representing the deviation from a perfect square, was measured in square microns. There was a large variation of the area values measured in currently available foldable IOLs labelled as square-edged lenses. As a group, the edges of hydrophilic acrylic lenses were less square than those of hydrophobic acrylic and silicone lenses. Hydrophobic acrylic AF-1 Hoya lenses had a high area value (329.7μ2). Through manufacturing changes, the edges of the lenses were then optimised to a value down to 39.1μ2, which represents the most square hydrophobic acrylic edge currently available.
منابع مشابه
Fulminant Panuveitis following Iris Suture Fixation of Posterior Chamber Intraocular Lens
We present a case of fulminant panuveitis following iris suture fixation of a posterior chamber intraocular lens. We hypothesize that the zonular dehiscence allowed the inflammatory cells in the anterior compartment to gain access to the posterior segment mimicking endophthalmitis or toxic anterior segment syndrome. Also certain bulky lens designs, like the current Rayner hydrophilic acrylic le...
متن کاملEvaluating and defining the sharpness of intraocular lenses: microedge structure of commercially available square-edged hydrophilic intraocular lenses.
PURPOSE To evaluate the microstructure of the edges of currently available hydrophilic acrylic intraocular lenses (IOLs) in terms of their deviation from an "ideal" square as a follow-up of preliminary in vitro studies of experimental poly(methyl methacrylate) IOLs and commercially available foldable hydrophobic IOLs. SETTING Berlin Eye Research Institute, Berlin, Germany. METHODS Twenty-fo...
متن کاملBiocompatibility of Intraocular Lenses
The performance of an intraocular lens is determined by several factors such as the surgical technique, surgical complications, intraocular lens biomaterial and design, and host reaction to the lens. The factor indicating the biocompatibility of an intraocular lens is the behavior of inflammatory and lens epithelial cells. Hence, the biocompatibility of intraocular lens materials is assessed in...
متن کاملImplantable collamer posterior chamber intraocular lenses: a review of potential complications.
PURPOSE To review the peer-reviewed literature reporting postoperative complications of the most recent models of Visian Implantable Collamer posterior chamber intraocular lenses (ICL, STAAR Surgical Co). METHODS A literature search of the PubMed database was performed to identify all articles related to ICL complications. Articles were obtained and reviewed to identify those that reported co...
متن کاملScanning electron microscopic characteristics of phakic intraocular lenses.
OBJECTIVE To analyze the surface quality of new generation phakic intraocular lenses (IOLs). DESIGN Experimental materials study. MATERIALS Three different new generation phakic IOLs: angle-fixated anterior chamber lens Chiron Vision NuVita MA20 (polymethylmethacrylate [PMMAD, iris-fixated anterior chamber lens Ophtec Artisan Iris-Claw (PMMA), posterior chamber lens Staar ICM (polymer from ...
متن کامل