Assessment of right atrial function with speckle tracking echocardiography after percutaneous closure of an atrial septal defect.
نویسندگان
چکیده
INTRODUCTION Speckle tracking echocardiography (STE) for two-dimensional (2D) strain analysis is a new tool to assess myocardial function. The aim of this study was to assess right atrial (RA) function using STE in patients with an atrial septal defect (ASD) before and one month after percutaneous closure. METHODS We prospectively examined 32 consecutive patients (nine male, 23 female) who underwent percutaneous transcatheter closure of a secundum ASD between June 2013 and December 2015. Echocardiography was performed on admission, prior to cardiac catheterization and then one month after ASD closure. Peak global RA longitudinal strain was analyzed by 2D-STE. RESULTS Patients' mean age was 34.6±8.2 years. The mean diameter of the occlusive devices was 18.5±7.5 mm. Right ventricular (RV) end-diastolic diameters were significantly increased but decreased significantly after ASD closure (43±5 vs. 38±4 mm, p<0.05). Left atrial (LA) diameters (40±8 vs. 37±6 mm, p<0.05) decreased significantly after the intervention, whereas left ventricular (LV) end-diastolic diameters (45±5 vs. 46±4 mm, NS) remained unchanged. Tricuspid annular plane systolic excursion increased significantly (17.6±5.4 vs. 22.3±8.1 mm, p<0.05). After closure of the defect, a significant increase was observed in longitudinal RA strain (26.5±9.6% vs. 35.3±10.5%, p<0.001). CONCLUSIONS After percutaneous transcatheter closure of a secundum ASD, there was an increase in RA longitudinal strain. 2D-STE strain analysis appears to be helpful for the assessment of RA function and of response to correction of volume overload after percutaneous transcatheter closure of a secundum ASD.
منابع مشابه
Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty
Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...
متن کاملAssesment of Right Ventricle Function with Speckle Tracking Echocardiography after the Percutaneous Closure of Atrial Septal Defect.
BACKGROUND Transthoracic echocardiography is used for assessment of right ventricular (RV) function. Speckle tracking echocardiography (STE) is a new tool to assess myocardial function. The aim of this study was to evaluate RV function using STE in patients with atrial septal defect (ASD) before and the first month after percutaneous closure. METHODS We prospectively examined 32 consecutive p...
متن کاملTwo-dimensional strain and strain rate imaging of the right ventricle in adult patients before and after percutaneous closure of atrial septal defects.
AIMS Echocardiographic speckle tracking or two-dimensional (2D) strain analysis is a new tool to assess myocardial function. This prospective controlled study evaluates systolic right ventricular (RV) function by 2D strain in adult patients with atrial septal defect (ASD) before and 3 months after percutaneous closure. METHODS AND RESULTS Assessment of global longitudinal strain (GLS), global...
متن کاملUrgent Surgical Intervention for Embolized Cardiac Occluder Devices: A Case Series
Introduction: In this study, we sought to illustrate our experience in urgent surgical management for embolized cardiac septal occlude devices resulting from trans-catheter closure of atrial septal defect and ventricular septal defect. Mathrials and Methods: We retrospectively reviewed four patients aged 2–10 years who underwent urgent surgery due to cardiac septal occluder embolization between...
متن کاملA failed case of percutaneous septal closure of fenestrated atrial septal defect.
A patient presenting with a history of palpitation and exertional dyspnea was initially diagnosed with two separate secundum-type atrial septal defects by transesophageal echocardiography. Subsequent transesophageal echocardiography, after failure of closure with two separate closure devices, showed another defect and an ongoing left to right shunt. During surgery, more defects were observed. T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology
دوره 36 12 شماره
صفحات -
تاریخ انتشار 2017