The relationship between intravenous infusate colonisation and fluid container hang time.

نویسندگان

  • Claire M Rickard
  • Boun Vannapraseuth
  • Matthew R McGrail
  • Lorraine J Keene
  • Sam Rambaldo
  • Chloe A Smith
  • Gillian Ray-Barruel
چکیده

AIMS To examine the level of microbial colonisation in intravenous fluids after 24 hours of use in an acute care setting to determine the necessity of changing infusate bags on a time-related basis. BACKGROUND Catheter-related bloodstream infections are a serious and life-threatening complication of intravascular devices. Colonised intravenous fluids are one potential source of infection; however, there is little published literature on incidence rates and few recent studies. Routine intravenous fluid replacement has been advocated as an infection control method, but the effectiveness of this is unknown and the optimal duration for infusate use remains uncertain. DESIGN Cross-sectional study over 18 months in a 257-bed teaching hospital. METHODS Infusate specimens (n = 264) were obtained from crystalloid fluids that had been used for 24 hours or more. Microbiological culture and sensitivity testing was performed and infusate-related bloodstream infection (IRBSI) rates were recorded. Sample testing of previously unopened intravenous solutions acted as a control. RESULTS The infusate colonisation rate was 0.4%, or 0.09 per 1000 infusion hours. The only isolated organism was coagulase-negative Staphylococcus. Infusions had been in use for 24-185 hours (1-8 days). There was no difference in median duration of use for colonised (35.0 hours) and sterile (34.0 hours) specimens (Mann-Whitney test, p = 0.99). There were no cases of IRBSI. CONCLUSION The incidence of intravenous fluid colonisation and the risk of related bloodstream infection are low even after several days of infusate use. Current practice appears to successfully maintain the sterility of intravenous fluids. RELEVANCE TO CLINICAL PRACTICE Routine replacement of intravenous fluids continues in many settings, often 24 hourly, in the belief that this prevents infection. We found no relationship between duration of use and colonisation and routine replacement may be unnecessary. Further research is needed to investigate the effectiveness of routinely replacing intravenous fluids at set time points to prevent colonisation and infection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

"Consistent parallel relationships among myocardial oxygen consumption, coronary blood flow, and pericardial infusate adenosine concentration with various interventions and beta-blockade in the dog".

Coronary blood flow responds uniquely to changes in myocardial demand, regardless of the stimulus. If adenosine mediates this response, interstitial fluid adenosine concentration should also change in parallel with myocardial oxygen consumption and coronary blood flow during alterations of cardiac work. We tested this hypothesis by measuring coronary blood flow, myocardial oxygen consumption, a...

متن کامل

Reduction of catheter-associated sepsis in parenteral nutrition using low-dose intravenous heparin.

To assess whether adding low-dose heparin to the infusate of patients receiving parenteral nutrition reduced the incidence of septic complications related to the central venous catheter, 80 consecutive patients requiring intravenous feeding were studied. Half of these patients received heparin 1 unit/ml of infusate, while in the remaining 40 (controls) an equal volume of physiological saline wa...

متن کامل

Effective methods of in-line intravenous fluid warming at low to moderate infusion rates.

Three methods of warming intravenous (IV) fluids were examined. An in-line blood warmer was generally ineffective at flow rates of < 250 mL/hr but did produce temperatures of 30 to 31 degrees C at the catheter when the infusion rate was 500 to 1,000 mL/hr and the tubing was insulated. An in-line hot water bath produced temperatures of > or = 30 degrees C at flow rates of 200 to 1,000 mL/hr with...

متن کامل

Clinical and laboratory evaluation of a closed enteral feeding system under cyclic feeding conditions: a microbial and cost evaluation.

Cyclic feeding schedules are now commonly used in conjunction with closed enteral feeding systems. Some manufacturers and clinicians have speculated that closed system cyclic feeding may promote formula contamination via retrograde movement of bacteria during the "no-flow" periods. Using both laboratory and clinical settings, our study evaluated whether retrograde bacterial movement under "no-f...

متن کامل

The effect of increased intravenous fluid intake on the course and outcome of labor in nulliparous women in Dr. Shariati Hospital, Bandar Abbas-2003

Introduction: Factors that affect the progress of labor have been studied extensively in an effort to improve labor progress. One variable that has been studied minimally, is the effect of adequate maternal hydration. This study aimed to determine the effect of increased intravenous fluid on the course of labor in nulliparous women in Bandar Abbas Dr. Shariati hospital in 2003. Methods: In thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical nursing

دوره 18 21  شماره 

صفحات  -

تاریخ انتشار 2009