Meta-analysis: computed tomographic colonography.

نویسندگان

  • Brian P Mulhall
  • Ganesh R Veerappan
  • Jeffrey L Jackson
چکیده

BACKGROUND Computed tomographic (CT) colonography, also called virtual colonoscopy, is an evolving technology under evaluation as a new method of screening for colorectal cancer. However, its performance as a test has varied widely across studies, and the reasons for these discrepancies are poorly defined. PURPOSE To systematically review the test performance of CT colonography compared to colonoscopy or surgery and to assess variables that may affect test performance. DATA SOURCES The PubMed, MEDLINE, and EMBASE databases and the Cochrane Controlled Trials Register were searched for English-language articles published between January 1975 and February 2005. STUDY SELECTION Prospective studies of adults undergoing CT colonography after full bowel preparation, with colonoscopy or surgery as the gold standard, were selected. Studies had to have used state-of-the-art technology, including at least a single-detector CT scanner with supine and prone positioning, insufflation of the colon with air or carbon dioxide, collimation smaller than 5 mm, and both 2-dimensional and 3-dimensional views during scan interpretation. The evaluators of the colonogram had to be unaware of the findings from use of the gold standard test. Data on sensitivity and specificity overall and for detection of polyps less than 6 mm, 6 to 9 mm, and greater than 9 mm in size were abstracted. Sensitivities and specificities weighted by sample size were calculated, and heterogeneity was explored by using stratified analyses and meta-regression. DATA SYNTHESIS 33 studies provided data on 6393 patients. The sensitivity of CT colonography was heterogeneous but improved as polyp size increased (48% [95% CI, 25% to 70%] for detection of polyps <6 mm, 70% [CI, 55% to 84%] for polyps 6 to 9 mm, and 85% [CI, 79% to 91%] for polyps >9 mm). Characteristics of the CT colonography scanner, including width of collimation, type of detector, and mode of imaging, explained some of this heterogeneity. In contrast, specificity was homogenous (92% [CI, 89% to 96%] for detection of polyps <6 mm, 93% [CI, 91% to 95%] for polyps 6 to 9 mm, and 97% [CI, 96% to 97%] for polyps >9 mm). LIMITATIONS The studies differed widely, and the extractable variables explained only a small amount of the heterogeneity. In addition, only a few studies examined the newest CT colonography technology. CONCLUSIONS Computed tomographic colonography is highly specific, but the range of reported sensitivities is wide. Patient or scanner characteristics do not fully account for this variability, but collimation, type of scanner, and mode of imaging explain some of the discrepancy. This heterogeneity raises concerns about consistency of performance and about technical variability. These issues must be resolved before CT colonography can be advocated for generalized screening for colorectal cancer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevalence and risk factors for post-investigation colorectal cancer (“interval cancer”) after computed tomographic colonography: protocol for a systematic review

BACKGROUND Colorectal cancer (CRC) is a common and important disease. There are different tests for diagnosis, one of which is computed tomographic colonography (CTC). No test is perfect, and patients with normal CTC may subsequently develop CRC (either because it was overlooked originally, or because it has developed in the interim). This is termed post-investigation colorectal cancer (PICRC) ...

متن کامل

Accuracy of computed tomographic colonography for the detection of polyps and colorectal tumors: a systematic review and meta-analysis.

BACKGROUND The real accuracy of computed tomographic colonography (CTC) is still unknown. OBJECTIVE To perform a meta-analysis of the diagnostic accuracy of CTC for the detection of polyps and colorectal tumors. METHODS SELECTION OF STUDIES Studiesassessing the accuracy of CTC for the detection of colorectal polyps and tumors were selected. data synthesis: Meta-analyses combining sensiti...

متن کامل

Performance of computed tomographic colonography for the screening of colorectal polyp in acromegalic patients: a prospective study.

CONTEXT Acromegalic patients have better chances to develop colorectal polyps and cancer and, considered a high-risk group, need to undergo frequent screening examinations. Moreover, in acromegalia, the increased bowel length and the intestinal loop complexity can lead to higher levels of technical difficulties and increase the risks of complications at conventional colonoscopy. Computed tomogr...

متن کامل

Evaluation of contrast-enhanced computed tomographic colonography in detection of local recurrent colorectal cancer.

AIM To evaluate the diagnostic accuracy, sensitivity, specificity of contrast-enhanced computed tomographic colonography in detecting local recurrence of colorectal cancer. METHODS From January 2000 to December 2004, 434 patients after potentially curative resection for invasive colorectal cancer were followed up for a period ranging from 20 to 55 mo. Eighty of the four hundred and thirty-fou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of internal medicine

دوره 142 8  شماره 

صفحات  -

تاریخ انتشار 2005