Inappropriate cardioverter-defibrillator discharge continues to be a major problem in clinical practice.
نویسندگان
چکیده
BACKGROUND The purpose of this study was to determine the rate and causes of inappropriate rhythm detection, and to compare adequacy of ventricular arrhythmia detection by single-chamber and dual-chamber cardioverter-defibrillators (ICD). METHODS We evaluated 190 patients (age 57.2 +/- 11.2 years) with ICD. FOLLOW-UP 34.3 +/- +/- 22 months. Dual-chamber ICD was used in 54 patients. RESULTS We evaluated 2244 arrhythmia events recognized as of ventricular origin, including ventricular tachycardia and ventricular fibrillation. 431 events (19.2%) were recognized erroneously and resulted in an inappropriate ICD discharge. Most cases of inappropriate therapies (182 events, 42.23%) were due to atrial fibrillation or flutter. Overall, inappropriate arrhythmia detection was found in 64 (33.6%) of 190 patients. In terms of the number of affected patients, the most common cause of inappropriate ICD discharge was sinus tachycardia - 23 (12.1%) patients, followed by atrial fibrillation - 16 (8.4%) patients. Among 54 patients with dual-chamber ICD, inappropriate therapy was noted in 21 (38.8%) patients, (T wave oversensing, sinus tachycardia and atrial fibrillation etc.). No significant difference was seen in the rate of inappropriate therapy due to a rapid supraventricular rhythm between patients with single-chamber versus dual-chamber ICD. In contrast, patients with single-chamber ICD more often experienced inappropriate therapy due to atrial fibrillation (155 vs. 28 patients) and sinus tachycardia (66 vs. 9 patients). CONCLUSIONS Despite of introduction of new generations of ICDs, the problem of inappropriate ICD discharge could not be eliminated. The major problem is distinction between supraventricular arrhythmia and ventricular tachyarrhythmia.
منابع مشابه
THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملThe Role of the Wearable Cardioverter- Defibrillator In Contemporary Clinical Practice
The implantable cardioverter-defibrillator (ICD) has been shown to improve survival in patients at high risk for sudden cardiac arrest (SCA). However, there remain situations in which an ICD may be inappropriate: the high risk for SCA is temporary, there is need for interruption of implanted ICD therapy (e.g. for infection), there is temporary inability to implant an ICD, there is bridge period...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملClinical profile and incidence of ventricular arrhythmia in patients undergoing defibrillator generator replacement in Spain.
INTRODUCTION AND OBJECTIVES Implantable cardioverter-defibrillators reduce mortality in some patients with heart disease. Battery replacement is a frequent occurrence in clinical practice and is required in up to 30% of implants. The benefit/risk ratio of defibrillators varies over time and should be reevaluated at the time of replacement. The aim of this study was to determine the clinical cha...
متن کاملRepeat inappropriate defibrillator discharges following defibrillator implantation. What is the mechanism and treatment?
Introduction Inappropriate shocks from implantable cardioverterdefibrillator (ICD) devices are a well-described clinical problem that contributes to patient morbidity and mortality. There are a number of causes for inappropriate ICD discharge, and T-wave oversensing (TWOS) is one such example. Improvements in ICD sensing algorithms have reduced the incidence of inappropriate therapies but have ...