Inter-element fractionation and correction in laser ablation inductively coupled plasma mass spectrometry
نویسنده
چکیده
Inter-element fractionation in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) analysis is one of the major challenges for using the technique for in situ trace element determination and isotopic ratio measurement of geological, environmental and biological solid samples. Attempts have been made to reduce inter-element fractionation in LA-ICP-MS analysis. However, this fractionation cannot be eliminated. The mechanism of the fractionation in LA-ICP-MS analysis is not very well understood. This study investigated the inter-element fractionation of seven elements (Ca, V, Zn, Ga, Sr, La and Nd) in three different sample matrices (NIST 613, BCR-2 and SY-4) using a UV 266 nm laser. The study showed that the inter-element fractionation depends on the sample matrices and varies with time. The inter-element fractionation behaviour of V, Zn and Ga in the synthetic silicate glass NIST 613 is different from that in the quenched glass of fused silicate rocks (BCR-2 and SY-4). Relative to Ca, V, Zn and Ga show less fractionation in NIST 613 but larger fractionation in BCR-2 and SY-4. The relative internal standard normalized element intensity (RISNEI) is not linear with time for a laser ablation period of 210 s. Therefore, data acquisition using prolonged laser ablation without a matrix match will not improve the precision and accuracy for elements whose fractionation behavior is different from that of the internal standard element. The RISNEI versus time relationship for the ®rst 100 s laser ablation can be treated as linear to simplify the data calculation. In this paper, the internal standard normalized fractionation factor (ISNFF) is de®ned as the sum of the second half average RISNEI and the difference between the second and ®rst half average RISNEI, divided by the second half RISNEI of data acquisition, for the analyte concentration calculation. The ISNFF was applied for the correction of the data reduction in LA-ICP-MS analysis. The data accuracy for these seven elements is generally improved, particularly for an element whose calibration standard normalized ISNFF is signi®cantly greater or less than 1 (e.g., Zn and Ga in this study). Good accuracy can be obtained for elements without ISNFF correction and matrix matches only if the calibration standard normalized ISNFF of the elements is close to 1.
منابع مشابه
The effect of ultrafast laser wavelength on ablation properties and implications on sample introduction in inductively coupled plasma mass spectrometry.
We investigated the role of femtosecond (fs) laser wavelength on laser ablation (LA) and its relation to laser generated aerosol counts and particle distribution, inductively coupled plasma-mass spectrometry (ICP-MS) signal intensity, detection limits, and elemental fractionation. Four different NIST standard reference materials (610, 613, 615, and 616) were ablated using 400 nm and 800 nm fs l...
متن کاملLaser Ablation Inductively Coupled Plasma
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is one of the most successful direct solid sampling techniques for major, minor and trace element analysis. However, this technique still suffers from matrix dependent ablation characteristics, which makes quantification very difficult. Furthermore, the laser sampled material alters its composition from the sample to the de...
متن کاملMultivariate pattern matching of trace elements in solids by laser ablation inductively coupled plasma-mass spectrometry: source attribution and preliminary diagnosis of fractionation.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) is used with two variations of principal components analysis (PCA) for objective, routine comparisons of forensic materials without time-consuming and destructive sample dissolution. The relative concentrations of trace elements in a solid sample are examined to provide a "fingerprint" composition that can be used for identi...
متن کاملAnalyte response in laser ablation inductively coupled plasma mass spectrometry.
The dependence of analyte sensitivity and vaporization efficiency on the operating parameters of an inductively coupled plasma mass spectrometer (ICPMS) was investigated for a wide range of elements in aerosols, produced by laser ablation of silicate glass. The ion signals were recorded for different carrier gas flow rates at different plasma power for two different laser ablation systems and c...
متن کاملTemporal changes of size distribution of mass and relative intensity for ablated particles during laser ablation inductively coupled plasma mass spectrometry
To investigate elemental fractionation during laser ablation-inductively coupled plasma mass spectrometry (LA-ICPMS) we measured mass fractions of ablated particles and chemical composition of ablated particles in this study. Temporal changes of fractionation indexes (FIs) were investigated under laser defocus conditions which caused a large variation of size distribution of abated particles. I...
متن کامل