Pilot scale evaluation of mine water (MW) as a cooling medium

نویسندگان

  • JS Swart
  • JP Engelbrecht
چکیده

Sasol One abstracts large volumes of water from various sources, such as the Zuikerbosch & Vaal River for various applications including make-up to the cooling water systems. In an attempt to evaluate the use of underground MW as an alternative cooling medium, two pilot-scale cooling towers (CTs) were used. Data of five runs (3 weeks each) at different linear flow velocities (LFVs) and cycles of concentration (COC) were obtained. A prescribed chemical treatment program from a local supplier was also evaluated. Mild steel corrosion coupons and heat exchanger tubes were used to monitor the fouling, scaling and corrosion rates. An experimental design program was followed to determine the layout of the different experimental runs. The respective indices indicate the presence of low scaling and corrosion rates in the CTs which correspond well with that obtained from the analyses of the coupons and heat exchanger tubes (1.5 to 11.0 mg/dm2/d and 0.04 to 0.21 mm/y, respectively). In addition, the fouling rates (2.8 to 27 mg/dm2/d) obtained during the five runs indicate the presence of sessile bacteria in the system. According to the supplier, the total cost of the chemical treatment program used during the pilot-scale test work is comparable to the current cost for the commercial cooling systems at Sasol One. It is evident from the results obtained during this study that the use of underground MW as a cooling medium is a viable option. However, the work conducted in this study was only a first effort and it is possible that the high levels of sulphate (up to 966 mg/ l) in the make-up water could result in concrete corrosion, which could have a detrimental effect on the integrity of the cooling tower structures. In addition, the variability in the MW quality, which was not considered during the experimental period, could be problematic since it will complicate the chemical treatment of this water in a full scale cooling tower system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis of Heat Exchanger Scales in Cooling Water Systems

An experimental database is compiled in order to fingerprint the scales formed over the hot surfaces of heat exchangers, in cooling water systems or other systems with similar chemistry. To collect these data, a dynamic simulating pilot plant was designed with considerable application flexibility among which simultaneous flow of water with different velocity and heat fluxes to three simulat...

متن کامل

Modeling of a Geothermal Cycle Condenser in a Combined Diesel Power Cycle: Case Study of 42 MW Diesel Power Plant in Moghan and Ardabil

This paper presents the results of a research into the feasibility of recovering waste heat and determining design parameters of a recovery boiler for a set of medium-speed diesel generators with a capacity of 7 MW (the nominal capacity of all units is 42 MW, which would be a study on a unit). And is used to generate electricity. The main purpose of this study is to design a thermal waste recov...

متن کامل

Pilot-scale cooling tower to evaluate corrosion, scaling, and biofouling control strategies for cooling system makeup water.

Pilot-scale cooling towers can be used to evaluate corrosion, scaling, and biofouling control strategies when using particular cooling system makeup water and particular operating conditions. To study the potential for using a number of different impaired waters as makeup water, a pilot-scale system capable of generating 27,000 kJ∕h heat load and maintaining recirculating water flow with a Reyn...

متن کامل

Use of a pilot scale heat exchanger-cooling tower system for the evaluation of mineral scale inhibitors

A pilot heat exchanger – cooling tower prototype was constructed and used for the evaluation of scale inhibitors in the inhibition of calcium carbonate (CaCO3) precipitation and deposition. The chemical additives that were used as inhibitors were 2phosphonobutane-1,2,4-tricarboxylic acid (PBTC, Dequest 7000), bis(hexamethylene triaminepenta (methylenephosphonic acid)) (BHPMP, Dequest 2090) and ...

متن کامل

Thermodynamic diagnosis of a novel solar-biomass based multi-generation system including potable water and hydrogen production

In this study, a new proposed multi-generation system as a promising integrated energy conversion system is studied, and its performance is investigated thermodynamically. The system equipped with parabolic trough collectors and biomass combustor to generate electricity, heating and cooling loads, hydrogen and potable water. A double effect absorption chiller to provide cooling demand, a proton...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004