Mitral valve repair with Carpentier-McCarthy-Adams IMR ETlogix annuloplasty ring for ischemic mitral regurgitation: early echocardiographic results from a multi-center study.

نویسندگان

  • Masao Daimon
  • Shota Fukuda
  • David H Adams
  • Patrick M McCarthy
  • A Marc Gillinov
  • Alain Carpentier
  • Farzan Filsoufi
  • Vivian M Abascal
  • Vera H Rigolin
  • Sacha Salzberg
  • Anna Huskin
  • Michelle Langenfeld
  • Takahiro Shiota
چکیده

BACKGROUND Ischemic mitral regurgitation (IMR) is associated with asymmetric changes in annular and ventricular geometry. Surgical repair with standard symmetric annuloplasty rings results in a high incidence of residual or recurrent mitral regurgitation (MR). The Carpentier-McCarthy-Adams (CMA) IMR ETlogix annuloplasty ring is the first remodeling ring specifically designed to treat asymmetric leaflet tethering and annular dilatation. We used quantitative 2-dimensional echo to examine early results of mitral valve (MV) repair with the CMA IMR ETlogix annuloplasty ring in patients with IMR. METHODS AND RESULTS Fifty-nine patients (aged 68+/-12 years) with grade > or = 2+ IMR (graded on a scale of 0 to 4+) underwent MV repair with the CMA IMR ETlogix annuloplasty ring. We assessed the mitral annular diameter (MAD), tethering area (TA), and tenting height (TH) of the MV in 4-chamber, 2-chamber, and long axis views at mid-systole before and 3 to 10 days after surgery. After surgery, 57 of 59 (97%) patients had grade 0 or 1+ MR, whereas 2 patients had 2+ MR. MV repair with the CMA IMR ETlogix ring significantly reduced MAD, TA, and TH (P<0.001, for all 3 echo views), particularly in the long axis and 4-chamber views. CONCLUSIONS Surgical repair of IMR with the novel asymmetric CMA IMR ETlogix annuloplasty ring provided excellent early results with effective reduction of MR, MAD, and leaflet tethering. This novel etiology-specific strategy may result in improved outcomes in IMR patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mitral valve repair for ischemic mitral regurgitation using the Carpentier-McCarthy-Adams IMR ETlogix® ring: medium-term echocardiographic findings.

The aims of this study were to review the principles underlying use of the Carpentier-McCarthy-Adams IMR ETlogix® asymmetric annuloplasty ring for the treatment of chronic ischemic mitral regurgitation and to report medium-term clinical outcomes observed at our center. The in-hospital mortality rate was 2.8%. Echocardiography at hospital discharge confirmed the absence of mitral regurgitation i...

متن کامل

[Remodeling annuloplasty using a prosthetic ring designed for correcting type-IIIb ischemic mitral regurgitation].

INTRODUCTION AND OBJECTIVES The most common mechanism underlying ischemic mitral regurgitation is restricted leaflet motion during systole (Carpentier's type IIIb). Annuloplasty is the preferred technique for surgical repair. The new Carpentier-McCarthy-Adams IMR Etlogix prosthetic annuloplasty ring was designed specifically to address the particular peculiarities of this condition, principally...

متن کامل

اثر PercutaneousCoronary Intervention Elective بر بهبودی نارسایی ایسکمیک میترال

Introdution: Ischemic mitral regurgitation (IMR) remains one of the most complex and unresolved aspects of ischemic heart disease that the impact of percutaneous coronary intervention (PCI) on improvement of intensity of ischemic mitral regurgitation is not well clarified. Patients with coronary artery diseases and ischemic mitral regurgitation have a worse prognosis than the patients with coro...

متن کامل

Rigid, complete annuloplasty rings increase anterior mitral leaflet strains in the normal beating ovine heart.

BACKGROUND Annuloplasty ring or band implantation during surgical mitral valve repair perturbs mitral annular dimensions, dynamics, and shape, which have been associated with changes in anterior mitral leaflet (AML) strain patterns and suboptimal long-term repair durability. We hypothesized that rigid rings with nonphysiological three-dimensional shapes, but not saddle-shaped rigid rings or fle...

متن کامل

Have we found the surgical solution for ischemic mitral regurgitation?

The article by deVarennes et al in the current issue of Circulation details the outcomes in 44 patients with severe (4 ) Carpentier type IIIb ischemic mitral regurgitation undergoing mitral valve repair consisting of posterior leaflet extension with bovine pericardium, coupled with remodeling annuloplasty, with or without coronary revascularization.1 Dissatisfied with the long-term results of a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 114 1 Suppl  شماره 

صفحات  -

تاریخ انتشار 2006