Use of near-infrared spectroscopy in early determination of irreversible hemorrhagic shock.

نویسندگان

  • Jodie H Taylor
  • Kristine E Mulier
  • Dean E Myers
  • Greg J Beilman
چکیده

BACKGROUND In field situations, patient triage may require early determination of patients progressing to irreversible shock. We investigated the utility of near-infrared spectroscopy (NIRS) in early detection of irreversible hemorrhagic shock. METHODS Twenty instrumented pigs were treated with a protocol involving 35% blood volume hemorrhage, 90 minutes of shock, and stepwise resuscitation with lactated Ringer's. Hemodynamics and NIRS measurements of skeletal muscle (leg), stomach, and liver tissue oxyhemoglobin saturation (StO2) were measured at baseline, every 30 minutes during shock, and after each resuscitative step. Measurements were compared between animals that expired during resuscitation (unresuscitatable) and animals that survived all resuscitative steps (resuscitatable). RESULTS Neither global oxygen delivery, oxygen consumption, nor lactate distinguished resuscitatable from unresuscitatable animals. Invasive measurements of SvO2 did distinguish resuscitatable from unresuscitatable animals. After the first fluid bolus, both stomach and leg StO2 differed significantly between resuscitatable and unresuscitatable animals. Regression analysis revealed skeletal muscle (leg) StO2 obtained after the first resuscitative step was a significant mortality predictor despite resuscitation (r2=0.45) (p = 0.005). CONCLUSIONS Non-invasive NIRS monitoring of leg and stomach StO2 differentiates resuscitatable from unresuscitatable animals after the initial resuscitative bolus. Use of this non-invasive tool may guide appropriate use of resuscitative fluids and has possible point-of-care applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Protein and Moisture in Fishmeal by Near-Infrared Reflectance Spectroscopy and Multivariate Regression Based on Partial Least Squares

The potential of Near Infrared Reflectance Spectroscopy (NIRS) as a fast method to predict the Crude Protein (CP) and Moisture (M) content in fishmeal by scanning spectra between 1000 and 2500 nm using multivariate regression technique based on Partial Least Squares (PLS) was evaluated. The coefficient of determination in calibration (R2C) and Standard Error of Calibra...

متن کامل

Potential of Near-Infrared Reflectance Spectroscopy (NIRS) to Predict Nutrient Composition of Bromus tomentellus

Determination of forage quality of available species is one of the fundamentalfactors for the management of rangelands. Near-Infrared Reflectance Spectroscopy (NIRS)was used to analysis the Nitrogen (N), Acid Detergent Fiber (ADF), Dry MatterDigestibility (DMD) and Metabolizable Energy (ME) content of three phenological stages(vegetative, flowering and seeding) of Bromus tomentellus samples in ...

متن کامل

Determining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings

Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...

متن کامل

Monitoring trauma and intensive care unit resuscitation with tissue hemoglobin oxygen saturation

INTRODUCTION The purpose of the present review is to review our experience with near-infrared spectroscopy (NIRS) monitoring in shock resuscitation and predicting clinical outcomes. METHODS The management of critically ill patients with goal-oriented intensive care unit (ICU) resuscitation continues to evolve as our understanding of the appropriate physiologic targets improves. It is now reco...

متن کامل

Determining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings

Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of trauma

دوره 58 6  شماره 

صفحات  -

تاریخ انتشار 2005