A multicenter, single-blind, prospective randomized trial to evaluate the safety of a polyethylene glycol hydrogel (Duraseal Dural Sealant System) as a dural sealant in cranial surgery.
نویسندگان
چکیده
OBJECTIVE Incisional cerebrospinal fluid (CSF) leakage after cranial surgery is a significant cause of morbidity due to poor wound healing and infection, meningitis, and pseudomeningocele formation. Many common dural closure techniques, such as sutures, autologous grafts, gelatin or collagen sponges, and fibrin glues, are used to achieve watertight closure, although none are US Food and Drug Administration approved for this use. DuraSeal Dural Sealant System is a polyethylene glycol (PEG) hydrogel approved by the U.S. Food and Drug Administration for obtaining watertight dural closure when applied after standard dural suturing. This multicenter, prospective randomized study further evaluated the safety of a PEG hydrogel compared with common dural sealing techniques. METHODS A total of 237 patients undergoing elective cranial surgery at 17 institutions were randomized to dural closure augmented with the PEG hydrogel or a control "standard of care" dural sealing technique after Valsalva maneuver demonstrated an intraoperative nonwatertight dural closure. Data were collected on complications resulting in unplanned postoperative interventions or reoperations, surgical site infections, CSF leaks, and other neurological complications within 30 days. Surgeons also provided data on the ease of use of the dural sealing techniques, as well as preparation and application times. RESULTS The incidences of neurosurgical complications, surgical site infections, and CSF leaks were similar between treatment and control groups, with no statistically significant difference between the measures. In the PEG hydrogel group (n = 120), the incidence of neurosurgical complications was 5.8% (n = 7), the incidence of surgical site infections was 1.7% (n = 2), and the incidence of CSF leak was 0.8% (n = 1). In the control group (n = 117), the incidence of neurosurgical complications was 7.7% (n = 9), the incidence of surgical site infection was 2.6% (n = 3), and the incidence of CSF leak was 1.7% (n = 2). Sealant preparation time was less than 5 minutes in 96.6% of the PEG hydrogel group compared with 66.4% of controls (P < 0.001). The dural augmentation was applied in less than 1 minute in 85.7% of the PEG hydrogel group compared with 66.4% of the control group (P < 0.001). CONCLUSIONS The PEG hydrogel dural sealant used in this study has a similar safety profile to commonly used dural sealing techniques when used as dural closure augmentation in cranial surgery. The PEG hydrogel dural sealant demonstrated faster preparation and application times than other commonly used dural sealing techniques.
منابع مشابه
A Cost-benefit Analysis of Using Polyethylene Glycol Hydrogel Sealant versus Fibrin Glue as a Dural Sealant for Posterior Fossa Surgery in the United States
Background: Cerebrospinal fluid (CSF) leaks are a well-known complication of posterior fossa neurosurgery. The use of dural repair adjuncts has been associated with fewer CSF leaks and subsequently, lower medical costs. Objectives: To determine if the use of polyethylene glycol hydrogel sealant (DuraSeal dural sealant system [DuraSeal]), resulted in cost savings in the United States compared to...
متن کاملTwo alternative dural sealing techniques in posterior fossa surgery: (Polylactide-co-glycolide) self-adhesive resorbable membrane versus polyethylene glycol hydrogel
BACKGROUND Post-operative cerebrospinal fluid (CSF) leak in posterior fossa surgery remains a significant source of morbidity. TissuePatchDural (TPD), a novel impermeable adhesive membrane, was used to reinforce dural closure. A comparison with one of the most commonly used dural sealing devices, DuraSeal, has been made. METHODS A retrospective, single-center study was conducted on 161 patien...
متن کاملPostoperative Cervical Cord Compression Induced by Hydrogel Dural Sealant (DuraSeal®)
Cerebrospinal fluid (CSF) leakage is a potential complication of cranial and spinal surgery. Postoperative CSF leakage can induce delayed healing, wound infection and meningitis. DuraSeal® (Covidien, Waltham, MA, USA) is a synthetic product which has been increasingly used to facilitate watertight repair of dural defects after cranial and spinal surgery. Despite some advantages of Duraseal®, th...
متن کاملA Novel Absorbable Hydrogel for Dural Repair: Results of a Pilot Clinical Study
This report details a 47 patient, prospective, non-randomized, single-center clinical study to evaluate the safety and performance of a new synthetic dural sealant as an adjunct to standard surgical dural repair techniques to prevent cerebrospinal fluid (CSF) leakage. A consecutive series of patients scheduled for cranial and spinal intradural surgery each received standard dural closures. Afte...
متن کاملDelayed Cerebrospinal Fluid Leak after Watertight Dural Closure with a Polyethylene Glycol Hydrogel Dural Sealant in Posterior Fossa Surgery: Case Report
A polyethylene glycol (PEG) hydrogel sealant recently has been approved as an adjunct to sutured dural closure in Japan. We treated consecutive six patients with PEG hydrogel sealant in posterior fossa operation. Three of six cases suffered delayed cerebrospinal fluid (CSF) leak after watertight dural closure with the PEG hydrogel sealant, although there was no leak case which was treated with ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- World neurosurgery
دوره 78 5 شماره
صفحات -
تاریخ انتشار 2012