Limbus versus pupil center for ocular alignment measurement with corneal reflexes.

نویسندگان

  • J C Barry
  • A Backes
چکیده

PURPOSE To investigate the accuracy of ocular misalignment measurement, using corneal reflections. METHODS Corneal reflex positions were measured relative to two landmarks, the limbus center and the entrance pupil center, using high-resolution digital images for cyclopean gaze angles from 0 degree to 18.8 degrees (34.04 prism diopters; PD) to the right and to the left in 10 subjects. Distance h from the center of the corneal curvature to each landmark was determined from linear regressions and showed significant differences between both conditions: mean hlimbus was 5.243 mm, and mean hpupil was 4.884 mm. From these, limbus- and entrance-pupil-center-related Hirschberg ratios were determined as 11 degrees/mm (19.43 PD/mm) and 11.82 degrees/mm (20.92 PD/ mm), respectively; and ocular alignment was calculated for both conditions. Simulated angles of strabismus were calculated as the binocular difference between ocular alignment of the right and left eyes (condition 1), and as the monocular difference between the ocular alignment of right eyes and left eyes separately (condition 2). RESULTS Condition 1: Errors in simulated angles of strabismus were approximately twice as large for entrance pupil center compared with those in limbus-center-based evaluation; in the primary position, the 95% pupil-related confidence interval of the binocular difference was +/- 5.217 degrees (9.1 PD), compared with +/- 3.174 degrees (5.5 PD) for the limbus-related option. Condition 2: Errors were approximately equal. CONCLUSIONS The entrance pupil center is a less reliable landmark than is the limbus center for measuring ocular alignment by using corneal reflections, because of unreliable positions of the entrance pupil center; different mean Hirschberg ratios should be used in both conditions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new method for accurate and fast measurement of 3D eye movements.

Videooculography (VOG) is an eye movement measurement method used in the objective evaluation of vestibulo-ocular reflexes (VOR). An important requirement of VOG is to accurately estimate pupil center and ocular torsion, irrespective of drooping eyelids, eyelashes, corneal reflection, and blinking. Finding the accurate center of the pupil is particularly important in three-dimensional VOG, sinc...

متن کامل

Pupil location under mesopic, photopic, and pharmacologically dilated conditions.

PURPOSE To determine whether there are systematic changes in pupil location with changes in the state of pupil size and with other ocular variables. METHODS High-resolution images of the pupil of the eyes of 70 subjects were taken using an infrared-sensitive camera. Images were obtained under mesopic, photopic, and pharmacologically dilated conditions. From the images, the center and diameter...

متن کامل

Refractive Surgery Feature Story

H uman eyes are capable of six types of movement: x/y lateral shifts, z levelling, horizontal and vertical rotations, and cyclotorsion (rotation around the optical axis). Current laser technology for refractive surgery creates corneal alterations to correct refractive errors more accurately than in the past.1 Ablation profiles are based on the removal of tissue lenticules through sequential las...

متن کامل

[A new method to test vertical ocular deviations using perilimbal light reflexes].

BACKGROUND To develop a new diagnostic technique to determine vertical ocular deviations when the center of the pupil is covered by swollen eyelids in up- and downgaze. PATIENTS AND METHODS In upgaze (downgaze) the reflex of a diagnostic lamp held at about 50 cm distance from the patient is observed on the lower (upper) limbus. In the case of an asymmetric reflex, prisms are used to obtain sy...

متن کامل

Optical aberrations and alignment of the eye with age.

We explored the relative changes in ocular, corneal, and internal aberrations associated with normal aging with special emphasis in the role of ocular alignment and lens shape factor in the balance of aberrations. Ocular and corneal aberrations together with the angle kappa were measured for a 5-mm pupil diameter in 46 eyes with low refractive errors and ages ranging between 20 and 77 years. Th...

متن کامل