Initial Tests on First Full-size ECAL Endcap Crystals

نویسندگان

  • G. J. Davies
  • E. Auffray
  • P. Lecoq
  • R. Marcos
  • P. Sempere - Roldan
  • M. Schneegans
چکیده

At the end of last year the first full size ECAL endcap crystals were delivered to CERN.Thirty in number, they were produced to the final geometrical specifications; 220mm long with a rear square face of 30mm and a front square face of 28.6mm. All were delivered polished. The visual inspection , dimension, transmission, light yield and light yield uniformity tests carried out since are discussed , with particular emphasis on the light yield uniformity. The results are very encouraging. suggesting that the endcap crystals will not need uniformisation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First results on radiation damage in PbWO4 crystals exposed to a 20 GeV/c proton beam

We have exposed seven full length production quality crystals of the electromagnetic calorimeter (ECAL) of the CMS detector to a 20 GeV/c proton beam at the CERN PS accelerator. The exposure was done at fluxes of 10 p/cm/h and 10 p/cm/h and integral fluences of 10 p/cm and 10 p/cm were reached at both rates. The light transmission of the crystals was measured after irradiation and suitable cool...

متن کامل

CMS Central Hadron Calorimeter

We present a description of the CMS central hadron calorimeter. We describe the production of the 1996 CMS hadron testbeam module. We show the results of the quality control tests of the testbeam module. We present some results of the 1995 CMS hadron testbeam. The design of the CMS detector starts with the 4 T solenoidal magnet of length 13 m and inner diameter 5.9 m. The magnet determines many...

متن کامل

CMS information server CMS NOTE 1999 / 068 The Compact Muon Solenoid Experiment

We investigate the possibility of reducing the data size of the electromagnetic calorimeter(ECAL) of CMS. The Selective Readout is applied first to reduce the data size at a manageable level. Then various data compression methods are considered, and their performances are estimated using the data from the full simulation of the ECAL system. A reduction of the average event size by a factor of t...

متن کامل

CMS ECAL Calibration Strategy

The CMS Electromagnetic crystal Calorimeter (ECAL) must be precisely calibrated if its full potential performance is to be realized. Inter-calibration from laboratory measurements and cosmic ray muons will be available for all crystals and has been demonstrated to give good pre-calibration values at the start-up; some crystals will be also inter-calibrated using an electron beam. In-situ calibr...

متن کامل

Experimental Studies of High-speed Liquid Films on Downward-facing Surfaces for Ife Wet Wall Concepts

The fusion event in inertial fusion energy (IFE) reactors creates neutrons, photons and charged particles that can damage the chamber first walls. The Prometheus design study used a high-speed thin film of molten lead injected tangential to the wall to protect the upper endcap of the reactor chamber from damaging x-rays and target debris (1,2). To assure full chamber coverage, the film must rem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007