The influence of bicuspid aortic valves on the dynamic pressure distribution in the ascending aorta: a porcine ex vivo model.
نویسندگان
چکیده
OBJECTIVES The aim of the study was to simulate the effect of different bicuspid aortic valve configurations on the dynamic pressure distribution in the ascending aorta. METHODS Aortic specimens were harvested from adult domestic pigs. In Group 1, bicuspidalization was created by a running suture between the left and the right coronary leaflets (n = 6) and in Group 2 by a running suture between the left and the non-coronary leaflets (n = 6). Eleven tricuspid specimens served as controls. Two intraluminal pressure catheters were positioned at the concavity and the convexity of the ascending aorta. The specimens were connected to a mock circulation (heart rate: 60 bpm, target pressure: 95 mmHg). A comparison of the different conditions was also done in a numerical simulation. RESULTS At a distal mean aortic pressure of 94 ± 10 mmHg, a mean flow rate of 5.2 ± 0.3 l/min was achieved. The difference of maximal dynamic pressure values (which occurred in systole) between locations at the convexity and the concavity was 7.8 ± 2.9 mmHg for the bicuspid and 1.0 ± 0.9 mmHg for the tricuspid specimens (P < 0.001). The numerical simulation revealed an even higher pressure difference between convexity and concavity for bicuspid formation. CONCLUSIONS In this hydrodynamic mock circulation model, we were able to demonstrate that bicuspid aortic valves are associated with significant pressure differences in different locations within the ascending aorta compared with tricuspid aortic valves. These altered pressure distributions and flow patterns may further add to the understanding of aneurismal development in patients with bicuspid aortic valves and might serve to anticipate adverse aortic events due to a better knowledge of the underlying mechanisms.
منابع مشابه
Phase contrast 4D flow in bicuspid aortic valves in a porcine model
Background Bicuspid aortic valves (BAV) are associated with aneurysms of the ascending aorta (AAA). It is unclear whether these aneurysms are caused by tissue alterations of the aortic wall or by alterations of blood flow in the ascending aorta due to the bicuspid valve morphology. In this study we analyzed the phase contrast 4D flow characteristics in normal tricuspid aortic valves (TAV) in a ...
متن کاملBicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملDilatation of the ascending aorta in patients with congenitally bicuspid aortic valves
INTRODUCTION The cause of ascending aortic dilatation occurring in patients with congenitally bicuspid aortic valves was investigated. METHODS Flow patterns through human aortic roots with congenitally bicuspid aortic valves as well as through porcine constricted aortas were studied in a left heart simulator. Vibration was recorded as a measure of turbulence in the post-stenotic segment. Hist...
متن کاملNumerical Simulations of Aortic Blood Flow with a Bicuspid Aortic Valve
Numerical Simulations of Aortic Blood Flow with a Bicuspid Aortic Valve By Ruth D. Blum One of the most common congenital heart defects is bicuspid aortic valve (BAV), occurring in about 1% to 2% of the population. In patients with BAV the aortic valve deviates from normal in that it only has two leaflets instead of three. BAV can result in altered hemodynamics and decreased performance of the ...
متن کاملBicuspid aortic valve is associated with altered wall shear stress in the ascending aorta.
BACKGROUND Hemodynamics may play a role contributing to the progression of bicuspid aortic valve (BAV) aortopathy. This study measured the impact of BAV on the distribution of regional aortic wall shear stress (WSS) compared with control cohorts. METHODS AND RESULTS Local WSS distribution was measured in the thoracic aorta of 60 subjects using 4-dimensional (4D) flow-sensitive magnetic resona...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 46 3 شماره
صفحات -
تاریخ انتشار 2014