Billowing Of Endologix Powerlink Stent Mimicking Endoleaks.
نویسندگان
چکیده
INTRODUCTION Endoleaks remains one of the primary concerns of endovascular aortic aneurysm repair (EVAR) and is routinely followed with CT angiography (CTA). However, certain imaging findings can mimic endoleaks. CASE PRESENTATION A 65-year-old woman who had endovascular aortic repair (EVAR) of an abdominal aortic aneurysm with Endologix Powerlink system developed marked new circumferential cauliflower-like bulging of contrast-filled sacs at mid-stent-graft with enlargement of the excluded aneurysm at 3-year follow-up. CONCLUSIONS Considering the unique construct of the Powerlink stents, this is thought to represent aneurysmal degeneration of the outer fabric material from the metal struts and may potentially pressurize the excluded sac with risk for rupture.
منابع مشابه
Multicenter trial of the PowerLink bifurcated system for endovascular aortic aneurysm repair.
PURPOSE The purpose of this study was to assess the results of abdominal aortic aneurysm repair with the PowerLink bifurcated endovascular graft (Endologix, Inc, Irvine, Calif). METHOD Twelve centers used the PowerLink bifurcated system for elective endovascular aneurysm repair in 118 patients recruited during a 16-month interval and followed for a 25-month interval (mean follow-up, 16 months...
متن کامل12-year Experience with the Endologix Powerlink Device in Endovascular Repair of Abdominal Aortic Aneurysms
Since Parodi reported the first successful endovascular aneurysm repair procedure in 1991, this procedure has gained wide acceptance for the treatment of abdominal aortic aneurysms in the past two decades. This minimally invasive approach has been proven effective and safe in the treatment of abdominal aortic aneurysm patients with lower early morbidity and mortality rates compared to open surg...
متن کاملEndovascular aortic aneurysm repair by a multidisciplinary team: lessons learned and six-year clinical update.
BACKGROUND Endovascular aneurysm repair (EVAR) (using an Federal Drug Association-approved AneuRx device) compared to conventional surgical repair of abdominal aortic aneurysm (AAA) previously rendered favourable outcomes regarding post-operative pain, avoidance of laparotomy, and rapid rehabilitation and hospital discharge in high-risk patients, including octagenarians. OBJECTIVES To assess ...
متن کاملFull title: Factors portending endoleak formation after thoracic aortic stent-graft repair of complicated aortic dissection Short title: Sze; Endoleaks after repair of aortic dissection
Background: Endoleaks after stent-graft repair of aortic dissections are poorly understood but appear substantially different from those seen after aneurysm repair. We studied anatomical and clinical factors associated with endoleaks in patients who underwent stent-graft repair of complicated type B aortic dissections. Methods and Results: From 2000 to 2007, 37 patients underwent stent-graft re...
متن کاملFactors portending endoleak formation after thoracic aortic stent-graft repair of complicated aortic dissection.
BACKGROUND Endoleaks after stent-graft repair of aortic dissections are poorly understood but seem substantially different from those seen after aneurysm repair. We studied anatomic and clinical factors associated with endoleaks in patients who underwent stent-graft repair of complicated type B aortic dissections. METHODS AND RESULTS From 2000 to 2007, 37 patients underwent stent-graft repair...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Research in cardiovascular medicine
دوره 5 2 شماره
صفحات -
تاریخ انتشار 2016