The completeness and reliability of threshold and false - discovery - rate source extraction algorithms for compact continuum sources
نویسندگان
چکیده
A International Centre for Radio Astronomy Research, M468, University of Western Australia, Crawley, WA 6009, Australia B Australian Astronomical Observatory, P.O. Box 296, Epping NSW 1710, Australia C CSIRO Astronomy & Space Sciences, Australia Telescope National Facility, P.O. Box 76, Epping NSW 1710, Australia D Sydney Institute for Astronomy, School of Physics, The University of Sydney, NSW 2006, Australia E School of Information Technologies, The University of Sydney, NSW 2006, Australia F ARC Centre of Excellence for All-sky Astrophysics (CAASTRO) G Email: [email protected]
منابع مشابه
New Catalogs of Compact Radio Sources in the Galactic Plane
Archival data have been combined with recent observations of the Galactic Plane using the Very Large Array to create new catalogs of compact centimetric radio sources. The 20 cm source catalog covers a longitude range of −20 < l < 120; the latitude coverage varies from ±0. 8 to ±2. 7. The total survey area is ∼ 330 deg; coverage is 90% complete at a flux density threshold of ∼ 13 mJy, and over ...
متن کاملDesign and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy
Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...
متن کاملThe False Discovery Rate in Simultaneous Fisher and Adjusted Permutation Hypothesis Testing on Microarray Data
Background and Objectives: In recent years, new technologies have led to produce a large amount of data and in the field of biology, microarray technology has also dramatically developed. Meanwhile, the Fisher test is used to compare the control group with two or more experimental groups and also to detect the differentially expressed genes. In this study, the false discovery rate was investiga...
متن کاملبررسی میزان کاملشماری ثبت سرطان مری در دادههای ثبت سرطان مبتنی بر جمعیت در استان اردبیل
Background and Objectives: completeness of registration is used as one of the measures of the quality of a cancer registry, which is the degree to which reportable incident cases of cancer in the population of interest is actually recorded in the registry. Methods: After removing the duplicates, a total of 471 new cases of esophagus cancer reported by three sources of pathology reports, medi...
متن کاملA new source detection algorithm using FDR
The False Discovery Rate (FDR) method has recently been described by Miller et al. (2001), along with several examples of astrophysical applications. FDR is a new statistical procedure due to Benjamini & Hochberg (1995) for controlling the fraction of false positives when performing multiple hypothesis testing. The importance of this method to source detection algorithms is immediately clear. T...
متن کامل